× All the transactions performed on 2.0 is available here. To access Market click "Home".

digital multimeter (aplab)(vc-97)

` 3,900.00

  • MRP: `4600.00

3.5 Digit LCD Display, supplied with test leads and battery.

  • Availability: 3 In Stock
  • Min. Qty. Per Consignee: 2
  • Display - 3.5 Digit
  • Measurement Type - Average
  • Count - 4000
  • AC Voltage Measurement Accuracy - 0.5 %
  • AC Current Measurement - 10 Ampere
Other Specifications Download Specification
Type Hand Held
Display 3.5 Digit
Measurement Type Average
Count 4000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.5 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.5 %
AC Current Measurement 10 Ampere
AC Current Measurement Accuracy 1.5 %
DC Current Measurement 10 Ampere
DC Current Measurement Accuracy 1.5 %
Resistance Measurement 40 Mega Ohm
Resistance Measurement Accuracy 1 %
Frequency Measurement 300 Kilo Hertz
Frequency Measurement Accuracy 100 %
Capacitance Mreasurement Range 1 to 200 Micro Fara
Capacitance Measurement Accuracy 2.5 %
Temperature Measurement -50 to 1000 Degree C
Temperature Measurement Accuracy 1.5 %
Feature Of Continuity Test And Diode Test Available
Feature Of Data Logging Not Available
If Data Logging Feature Is Available, Internal Memory min. 5000 points 200 readings
Computer Interface Alongwith Software Not Available
True RMS AC Voltage Band Width 100
Safety Rating Category II 600 V of IEC 61010.
Overload Protection Through Fuse
Operating Temperature Range 40-50 Deg. c
Operating Humidity (RH) 60-70
Power Requirements 230 V +-10 AC, 50 Hz +- 3 through Adaptor
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) CE
If Battery Operated, Type And No. Of Battery AAA
Total Voltage Of Battery 3
Standard Accessories Supplied With The Equipment TEST LEADS, BATTERY
Dimensions (H X W X L) 185 X 83 X 55 mm x mm x
Weight 300 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. EE/TR/MM/99
Test Report Date 22/12/2017
Name Of The Lab ELECTRONICS ELECTRICALS INDORE
Warranty 2 Year

Price Dekho Price Dekho Price List in india