temperature spectrum analyzer with scada probes (wiklog)(ap01wmst1)

` 691,200.00

  • Offered Price: ` 720000.00
  • MRP: `880000.00

Temperature detecting displaying and analysing equipment used at industrial and Institutional purpose and monitor a wide span of spectrum up to the full frequency range of the analyzer with stepped densitydisplay Focus on the signal of interest in a complex signal environment with effective triggering mechanism such as frequency mask trigger FMT and/or time qualified trigger TQT See small signals in the presence of large ones with up to 78 dB spurious-free dynamic range Eliminate the need for a dedicated instrument RTSA is an upgrade option for new and existing UXAs/PXAs/MXAs Go deeper and thoroughly analyze complex signals with 89600 VSA software. Calibration Options IEC 751 Class A accuracy Calibration schedule, resistance shift stabilised 1,000 hours at 400 C, 63.3 sensor response in water flowing at 3 ft/s 0.9 m/s, Insulation Resistance 500 x 106 ohms..

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Display Type - LCD Backlit SCADA Enabled
  • Capture/Demodulation Bandwidth (Max.) - 25 MHz
  • I/Q memory Depth (256 MB) - Yes
  • Traces Types - Normal (RMS), Average, Max. Hold, Min. Hold
  • Measurement Range (DANL to Max. Safe input Level) - 20 dBm/Hz - dBm
Other Specifications Download Specification
Frequency Range 20Hz - 3 GHz
Display Type LCD Backlit SCADA Enabled
Capture/Demodulation Bandwidth (Max.) 25 MHz
I/Q Memory Depth (256 MB) Yes
Trigger Free Run, Power Trigger, External
Traces Types Normal (RMS), Average, Max. Hold, Min. Hold
Sample Rate 100 Ms/s
Ref. Frequency Aging (1 X 10 ^ -7) 1 X 10 ^ -7
Measurement Range (DANL To Max. Safe Input Level) 20 dBm/Hz - dBm
Max. Safe Input Level (Should Be Less Than Or Equal To +30 DBm ) Yes
Displayed Average Noise Level ( 10 MHz To 3/6/13/26.5 GHz, DANL Should Be Less Than Or Equal To -130 DBm/Hz ) Yes
Modulation Analysis AM, FM, PM, BPSK, QPSK, Pi/4 DQPSK, 8PSK, 16SQAM, 32QAM, 64QAM, 128QAM, 256QAM, GMSK,GFSK
"Multi Domain Analysis With Stand Alone Software" Time, Frequency, Modulation, Spectrogram
Automatic Measurement (Time Mode) IQ vs Time, Power vs Time, Frequency vs Time, CCDF, crest factor, Pulse Measurements: Pulse Width, Pulse Peak Power, On/Off Ratio, Pulse Ripple, Pulse Repetition Interval, Duty Cycle Pulse-Pulse, Phase, Channel Power, Occupied BW, Frequency Deviation
Interface USB, LAN/GPIB
Operating Temperature 5 to 40 degree C and 80 % RH at 40 degree C
Power Requirements (230 +/- 10% VAC, 50 Hz) Yes
Rack Mount Kit For Signal Analyzer Yes
Availability Of The Test Report From Central Govt./ NABL/ ILAC Accredited Lab As Per Doc Correction Slip No. 38 Dtd 18/1/12 To Be Read In Conjunction With P&C Circular No. 71 Dtd 29/10/14 For Each Model Of Signal Analyzer. Yes
TTC No. & Date FFS9011
Name Of The Lab Ascon Labs
Address Of The Lab Indore
Type Test Reports Shall Consist Of Verification Of All The Features & Functional Parameters & Environmental Tests. Yes
Dry Heat Test: For 16 Hrs At A Temp. Of 55 Degree C In Accordance With IS: 9000/part-3/section-5/1977 (reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
Cold Test: For 4 Hrs At A Temp. Of (-)10 Degree C In Accordance With IS: 9000/part-2/section-4/1977(reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
Damp Heat Test: For 2 Cycles Of 24 Hrs (12 + 12h) Each At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981 (reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
The Scope Of Supply Shall Include One Set Of Operation And Maintenance Manual For Each Equipment. Yes