× All the transactions performed on 2.0 is available here. To access Market click "Home".

solar power meter analyzer and data logger (indusol)(ind6702)

` 312,000.00

  • Offered Price: ` 320000.00
  • MRP: `400000.00

This instrument is designed to measure Solar Power in the range in nanometers. The good Spectral Range, Orientation and Angular detection of meter allow users to conduct the most precise quantitative measurements of Solar Power Radiation Solar Power Measurement with Orientation and Tilt Angle, Easy measurement for rate of daylight penetration Auto change for measuring range Auto power off with disable functionInstantaneous display Ave/Min/Max values, 20 points memory, Socket of tripod mounting, Magnetic mount Backlit LCD and 4 digits triple display, Irradiance Display Range 01500 W/M2, Best Measurement Range of100-1250 W/m2 and Resolution 1W/m2 along with Temperature Display Range -30-125 Deg C plus effective Measurement Range 0-360 Deg C Resolution 1Deg Compass Bearing Measurement Range090 Resolution. Display Custom LCD Power Supply 2AA SCADA Installation and project level work of cable laying and converters for existing system configuration shall be extra chargeable..

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Display Type - LCD Backlit Backlit SCADA enabled
  • Capture/Demodulation Bandwidth (Max.) - 25 MHz
  • I/Q memory Depth (256 MB) - Yes
  • Traces Types - Normal (RMS), Average, Max. Hold, Min. Hold
  • Measurement Range (DANL to Max. Safe input Level) - 20 dBm/Hz - dBm
Other Specifications Download Specification
Frequency Range 20Hz - 3 GHz
Display Type LCD Backlit Backlit SCADA enabled
Capture/Demodulation Bandwidth (Max.) 25 MHz
I/Q Memory Depth (256 MB) Yes
Trigger Free Run, Power Trigger, External
Traces Types Normal (RMS), Average, Max. Hold, Min. Hold
Sample Rate 100 Ms/s
Ref. Frequency Aging (1 X 10 ^ -7) 1 X 10 ^ -7
Measurement Range (DANL To Max. Safe Input Level) 20 dBm/Hz - dBm
Max. Safe Input Level (Should Be Less Than Or Equal To +30 DBm ) Yes
Displayed Average Noise Level ( 10 MHz To 3/6/13/26.5 GHz, DANL Should Be Less Than Or Equal To -130 DBm/Hz ) Yes
Modulation Analysis AM, FM, PM, BPSK, QPSK, Pi/4 DQPSK, 8PSK, 16SQAM, 32QAM, 64QAM, 128QAM, 256QAM, GMSK,GFSK
"Multi Domain Analysis With Stand Alone Software" Time, Frequency, Modulation, Spectrogram
Automatic Measurement (Time Mode) IQ vs Time, Power vs Time, Frequency vs Time, CCDF, crest factor, Pulse Measurements: Pulse Width, Pulse Peak Power, On/Off Ratio, Pulse Ripple, Pulse Repetition Interval, Duty Cycle Pulse-Pulse, Phase, Channel Power, Occupied BW, Frequency Deviation
Interface USB, LAN/GPIB
Operating Temperature 5 to 40 degree C and 80 % RH at 40 degree C
Power Requirements (230 +/- 10% VAC, 50 Hz) Yes
Rack Mount Kit For Signal Analyzer Yes
Availability Of The Test Report From Central Govt./ NABL/ ILAC Accredited Lab As Per Doc Correction Slip No. 38 Dtd 18/1/12 To Be Read In Conjunction With P&C Circular No. 71 Dtd 29/10/14 For Each Model Of Signal Analyzer. Yes
TTC No. & Date CG01A321
Name Of The Lab Ascon Laboratories
Address Of The Lab Indore
Type Test Reports Shall Consist Of Verification Of All The Features & Functional Parameters & Environmental Tests. Yes
Dry Heat Test: For 16 Hrs At A Temp. Of 55 Degree C In Accordance With IS: 9000/part-3/section-5/1977 (reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
Cold Test: For 4 Hrs At A Temp. Of (-)10 Degree C In Accordance With IS: 9000/part-2/section-4/1977(reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
Damp Heat Test: For 2 Cycles Of 24 Hrs (12 + 12h) Each At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981 (reaffirmed 2004). The Analyzer Shall Be Checked For All The Functional Requirements Before And After 1-2 Hours Of Recovery Period After The Completion Of The Above Environmental Test. During The Last Half An Hour Of Conditioning Frequency Stability Shall Be Checked. And,the Result Shall Be Satisfactory. Yes
The Scope Of Supply Shall Include One Set Of Operation And Maintenance Manual For Each Equipment. Yes

Price Dekho Price Dekho Price List in india