Wireless PulseOximeterA Bluetooth Low Energy, Battery operated Device with diagnostic Oxygen Saturation measurement capability. Li-Po rechargeable battery, OLED display.Entire range of 0-100 saturationAccuracy 2 for 70-100, 3 for 50-69 same as allFingertip probeDual wavelength measurement.
Other Specifications Download Specification | |
---|---|
Pulse Meter For Testing Digital Taxi Meter With A Test Bench Having Capacity Of Testing 10 Meters At A Time With Different K Factor | Yes |
Adjustable K Factor For Different Meter | Yes |
Regulator For Speed Of Pulse Generator | Yes |
Battery Backup In Hours | 8 Hours |
Facility To Connect Any Type Of Meter With Testing Facilities For 10 Meters At A Time | Yes |
Test Kit/ Bench Capable Of Accommodating 10 Digital Taximeters At A Time, With Pulse And Time Generating/ Measuring Equipment, Suitable For Evaluating Normal Digital Taximeters That Calculate Fare For Journeys According To Defined Tariff | Yes |
The Unit Shall Consist Of Calibrated Pulse And Time Generators And Provision For Comparing The Meter Output. | Yes |
Built In Distance Measurement And Time Measurement Verification Capability. | Yes |
The Kit Shall Have Traceability To Standards. Provision For Indicating The Correction Factors For The Meter Shall Be Available. | Yes |
It Shall Be Possible To Set/ Regulate Varying Travelling Conditions Like Speed, Etc. | Yes |
The Test Rig Is To Be Supplied With Power Supply/ Adequate Battery Back Up To Required Voltage, At Least For 8 Hours Including The Device Under Test. | Yes |
Quick Type Connectors And Junction Terminals, As Required Display, Alarm And Output Report Printers May Be Attached. | Yes |
Pulse Meter Shall Be Capable To Calibrate Or Test Digital Taximeter As Per OIML R-21:2007(E) For Digital Taximeters And Meets The Requirement Of The Same. | Yes |
Each Meter (pulse Meter) & Timer Shall Be NPL/ERTL Calibrated With Trace Ability Certificate From The Same As It Shall Be Used As Standard Calibrator For Testing Of Digital Taxi Meter And Shall Also Be Available With Manufacturer For Verification Of The Product. | Yes |
Use Calibrated Standard Products For Manufacturing The Pulse Meters And Measurement Bench I.e. Digital Indicator To Indicate Calibration Data ,timer Etc. | Yes |
OILM-R-21:2007(E) For Taximeters Is For Guidance And All The Gazette Of India Related To Legal Metrology Issued Time To Time Are Applicable To The Specification As Well As To The Product. | Yes |
As Per The Gazette Of India Extraordinary, The Legal Metrology Act, 2009,cl. 22,Approval Of Model Before Manufacturing And Cl. 23,Prohibition On Manufacture, Repair Or Sale Without Licence For Product Shall Be Applicable On Manufacture Of Measuring Instrument | Yes |
Others Certificate Ie ROHS,WHO,GMP Etc. | Yes |
Availability Of Type Test Reports Of Product From Any ILAC/NABL Accredited/Central Gov. LAB. Showing Compliance To The Specification | Yes |
Test Report And Approvals To Be Furnished To The Buyer On Demand | Yes |
Test Cetificate No. | 27 |
Teat Report Date | 10/11/2017 |
Name Of The Lab Where Test Conducted. | Bangalore |
Warranty Time | 1 Year |
Product Code Available On Supplier Website | No |
If Yes,Product Code No. | Na |