Keysight Technologies DSOX3052T Digital Storage Oscilloscope - 500MHz - 2-Analog Channels 5GSa/s Sampling Rate, 4Mpts Memory with 8.5 inch capacitive touch screen, exclusive hardware base zone touch trigger with two-zone support, update rate of 1 million wfm/s, standard Gated FFT and Segmented Memory. Integrated 3-digit Digital Voltmeter and 8-digit Counter-totalizer. Wide range of hardware based serial protocol decodes options available for future upgrade like I2C, SPI, UART, CAN, CAN-FD, CAN symbolic, SENT, LIN, FlexRay, I2S, MIL-STD1553, ARINC429. 7-in-1 instrument integration Time/frequency domain correlation, 20MHz built-in Arbitrary waveform Generator and many more. DSOX3052T will be delivered with two nos. of 500MHz switchable passive probes, power cord, certificate of calibration, documentation CD. Standard 3 Year warranty and 3-Years Calibration Interval. Refer Keysight datasheet for detailed specifications. Prices indicated including GST@18 percent. Delivery period 6 weeks...
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Non -Windows |
Bandwidth Upgradability | Yes |
No. Of Analog Channels | 2 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points Mega Points |
Min. Detectable Pulse Width | NA ns ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 1mV/Div to 5 V/Div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, Ground on Screen |
Time Base Range | 1 ns/div to 50 s/div |
Trigger Types | Mode: Normal, Auto, Single, force and Type: Edge, Pulse, video, hardware based zone trigger, runt, setup/hold, pattern, burst etc. |
Measurements | 37 Built-in Automatic Measurement, math function-Two, displays FFT and one math simultaneously. Can be cascaded. Add, subtract, multiply, divide, differentiate, integrate, FFT, Ax + B, squared, square root, absolute value, common logarithm, natural logarithm, exponential, base 10 exponential, low pass filter, high pass filter, averaged value, smoothing, envelope, magnify, max hold, min hold, measurement trend, chart logic bus (Timing or State) |
Frequency Analysis Feature | No |
In-built Frequency Counter | Yes |
In-built Function Generator | No |
Acquisition Modes | Normal, Peak Detect, Averaging, High Resolution, Segmented |
Display Type | Colour |
Display Size | 8.5-Inch Capacitive Touch Screen Display CM CM |
I/O Interface | Standard USB Interface, LAN/ VGA/ GPIB Optional |
Standard Accessories To Be Supplied | Two Nos. of 10:1 Switchable Passive Probe, Power Chord, Certificate of Calibration, CD Containing Manual |
Operating Temperature Range | 0 to +55°C Degree C Degree C |
Operating Humidity (RH) | Up to 80% RH at or below +40°C % % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | PENANG4248247-5136877-1 |
Test Report Date | 21-SEPT-2017 |
Name Of The Lab | Keysight Technologies Malaysia |
Warranty | 3 Year |
Real Time Bandwidth | 500 MHz |
Record Length Per Analog Channel Simultaneously | Standard 4 Mpts, Standard segmented memory Mega Point Mega Point |
Sample Rate Per Analog Channel Simultaneously | 5 GSa/s half channels, 2.5 GSa/s all channels GS/sec GS/sec |
Waveform Update Rate | 1,000,000 wfrm/s Waveforms/ Waveforms/ |
Time Base Accuracy | 2 PPM |