3-voltage channels with wide measurement range 0 ... 1000 Vrms CAT III / 1000 V 4-current channels with support for automatic clamp recognition and on instrument range selection Automatic Smart Clamp detection and Smart Clamp range selection Compliance with power quality standard IEC61000-4-30 Class S Complete power quality analysis according to EN 50160 including signalling and inter harmonics Support for micro SD memory card 8-GBsupplied with the instrument up to 32GB Color-coded input terminals and terminal labels to suit your application region Intuitive main menu and large icons that makes the equipment very easy to navigate and configure Powerful PC SW PowerView3 enables downloading, view, analysis of recorded data and professional report creation Flexible clamps without additional power supply are included in the Euro set..
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Three phase |
Display Type | LCD Backlit |
Display Mode | 4.3 inch color TFT (480 x 272) |
Number Of Current Channels | 4 Nos. |
Number Of Voltage Channels | 4 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | Phase (L-N): 50 ÷ 1000 VRMS Volts |
Measurable Voltage Accuracy | ±0.5% of nominal voltage, |
Measurable Voltage Resolution | 10 mV, 100mV Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 50 m ÷ 1200 ARMS (with A1281 iron clamps) Ampere |
Measurable Current Accuracy | ±1.0% of m.v. (with A1281 iron clamps) |
Measurable Current Resolution | - Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 0.000 k ÷ 999.9 M KW |
Power Accuracy | ±1.0 % P |
Power Resolution | - Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | 42,5 ÷ 69,0 Hz ±10 mHz Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | 3 % UNom < UhN < 20 % UNom |
Resolution In Measurement Of Total Harmonics Distortion | 10 mV |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | 0th > 50th |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | ± 0.02 |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | - |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | - |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | 1.00 ÷ 10.00 |
Measurable Crest Factor Accuracy | ± 5 % · CFU |
Measurable Crest Factor Resolution | 0.01 |
Screen Memory | - |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | External memory 8 GB micro SD card MB |
Type Of Battery Used | 1.2 V NiMH rechargeable batteries type HR 6 (AA) |
Battery Backup | 3 Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 1000 Grams |
Dimensions(LXWXH) | 23 cm x 14cm x 8 cm cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | -20 DC ÷ +55 DC degree celsius |
Operating Humidity | 95 % RH (0 DC ÷ 40 DC), non-condensing % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | As per technical data Sheet |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | CAT-III 1000V,CAT-1V 600V |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | MI2883 |
TTC Report Date | 10-07-2014 |
Name Of Lab | Metrel |
Address Of Lab | Slovania |
Interface | RS232, USB and Ethernet |