1. Supports all types of earthing resistance measurements- A. Standard earthing resistance measurement with spikes- B. Selective earthing resistance test with one current clamp- C. Selective contact less earthing resistance with two current clamps- D. Specific earth resistance measurement, 2. Leakage current tests with current clamps 3. Load current tests with current clamps High accuracy, high immunity against external noise 4. Preprogrammed limits 5. PASS/FAIL evaluation of measurement result 6. Bright GREEN/RED indicators provides visual evaluation of results 7. Suited for testing on CAT IV installations 8. Magnetic holder enables hands-free operation 9. Built-in battery charger 10. Two level memory structure for saving test results and parameters 11. Basic downloading with EuroLink PRO PC SW package 12. Compatible with EuroLink PRO Plus PC SW package 13. USB and RS232 ports 14. Robust and ergonomic design.
Other Specifications Download Specification | |
---|---|
Display Type | 4 digit LCD display |
Measurable Earth Resistance Range | Auto ranging |
2-pole Method For Resistance Measurement | YES |
3-pole Method For Resistance Measurement | YES |
4-pole Method For Resistance Measurement | YES |
Number Of The Stakes | 4 NOS. |
Material Of The Stakes | GI |
Length Of The Stakes | 30 cm |
Diameter Of The Stakes | 10 MM cm |
Number Of The Test Leads | 4 Nos. |
Length Of The Test Leads | Earth test lead 4,5 m (blue) Earth test lead 4,5 m (red) Earth test lead 20 m (green) Earth test lead 20 m (black) cm |
No. Of Test Leads With Clamps | 4 Nos. |
Length Of Test Leads With Clamps | 1.5 cm |
Measuring Range1 For Earth Resistance | 0.00 ÷ 19.99 Ohms |
Measuring Range2 For Earth Resistance | 20.0 ÷ 199.9 Ohms |
Measuring Range3 For Earth Resistance | 200 ÷ 1999 Ohms |
Measuring Range4 For Earth Resistance | 2000 ÷ 9999 Ohms |
Measuring Range5 For Earth Resistance | N/A Ohms |
Measuring Range6 For Earth Resistance | N/A Ohms |
Measuring Range7 For Earth Resistance | N/A Ohms |
Measurable Earth Resistance Resolution For Range1 | 0.01 Ohms |
Measurable Earth Resistance Resolution For Range2 | 0.1 Ohms |
Measurable Earth Resistance Resolution For Range3 | 1 Ohms |
Measurable Earth Resistance Resolution For Range4 | 1 Ohms |
Measurable Earth Resistance Resolution For Range5 | N/A Ohms |
Measurable Earth Resistance Resolution For Range6 | N/A Ohms |
Measurable Earth Resistance Resolution For Range7 | N/a Ohms |
Measurable Earth Resistance Accuracy For Range1 | ±(3 % of reading + 3 digits) ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range2 | ±(3 % of reading + 3 digits) ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range3 | ± 5 % of reading ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range4 | ± 10 % of reading ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range5 | N/A ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range6 | N/A ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range7 | N/A ±% reading ± digits |
Stakeless Test(Clamp On) | yes |
Facility To Measure Earth Voltage | Not Available |
If Yes,Measurable Earth Voltage Range | N/A Volts |
If Yes,Measurable Earth Voltage Accuracy | N/A % |
Minimum Open Circuit Output Voltage | 40 VAC Volts |
Low Battery Indication | Available |
Over Range Indication | Available |
If Yes,Measurable Earth Voltage Resolution | N/A Volts |
Internal Memory | 1900 |
Type Of Battery Used In The Power Supply | rechargeable battery, size AA |
Battery Backup Time | typical 20 h Hours |
Battery Charger Provided With The Meter. | Yes |
Weight Of The Tester | 85 grams |
Dimensions(LXWXH) | 14 cm x 8 cm x 23 cm cmXcmXcm |
Provision For External SD Card | No |
Interface | USB and RS232 ports |
Operating Temperature Range | 0 °C ÷ 40 °C degree celsius |
Operating Humidity Range | 95 %RH (0 °C ÷ 40 °C), non-condensing % |
All Connecting Cables And Accessories To Be Supplied Along With The Tester. | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. | Earth test lead 4,5 m (blue) Earth test lead 4,5 m (red) Earth test lead 20 m (green) Earth test lead 20 m (black) Earth test rod, 4 pcs Power supply adapter + 6 NiMH rechargeable AA batteries Instruction manual on CD Short instruction manual Product verification data Handbook “Guide for testing and verification of low voltage installations” on CD |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. | Yes |
Type Test Report No. | MI3123 |
TTC Report Date | 10-07-2014 |
Name Of Lab | METREL DD |
Address Of Lab | SLOVENIA |