× All the transactions performed on 2.0 is available here. To access Market click "Home".

digital insulation tester 5 kva (mextechh)(5 kva)

` 85,668.00

  • MRP: `230890.00

Digital Insulation Tester 5 kva.

  • Availability: 2 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
  • Test Voltage - 50, 100, 250, 500 and 1000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - Yes
Other Specifications Download Specification
Type Hand Held
Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
Test Voltage 50, 100, 250, 500 and 1000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection NA
Pass Fail Function Yes
Data Logging more than 99 locations
Software Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 1 milliamper
Operating Temperature Range 0°C to 40 °C Degree C Degree C
Operating Humidity (RH) 95 % RH (0 DC to 40 DC), non-condensing %
Power Requirements Battery Operated
Type Of Battery 1.2 V NiMh Rechargable size AA Type
PC Interface Available
Standard Accessories Supplied With The Equipment Soft hand strap Test lead, 2 x 1.5 m Test probe, 2 pcs (black, red) Crocodile clip, 2 pcs (black, red) Power supply adapter + 6 NiMH rechargeable batteries, type AA Instruction manual on CD Short instruction manual Handbook
Dimensions (H X W X L) 140 x 80 x 230 mm mm x mm x
Weight 810 gms gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. M1153N
Test Report Date 23 May 2012
Name Of The Lab Mextech Engineering Lab
Warranty 1

Price Dekho Price Dekho Price List in india