× All the transactions performed on 2.0 is available here. To access Market click "Home".

cardiart- 9108 -12 channel ecg machine- bpl (bpl)(cardiart- 9108 -12 channel)

` 109,000.00

  • MRP: `122134.00

Simultaneous 12 Channel ECG Recording with 12 lead simultaneous acquisition.5.7- inch High Resolution Foldable Screen.QWERTY Alphanumeric keyboard.Built-in ECG Parameters measurements and Interpretation.Print Mode Pre-Sample/Real-Time Sample/Arrhythmia Triggered Sample.Upto 100 ECGs in Internal Memory.Supports External Archiving USB Drive for virtually unlimited ECG Data Storage.Built-in Rechargeable Lithium Ion Battery.Data transmission to PC Optional.TECHNICAL SPECIFICATIONSGENERALDisplay320 x 240 dot single colour LCDInput 100k, Sensitivity 10mm/V 5External Input / OutputOutput 100k, Sensitivity 1mm/V 5Communication InterfaceEthernet, Rs232 USBDimensions420mm x 330mm x 105mmECGInput CircuitFloating input circuit protection from defibrillation pace makersLeadStandard 12 leadsAcquisition Mode12 Leads SimultaneouslyA/D Convertor24 bitsInput Voltage Range 5mVp-pTime Constant3.2 SecondsFrequency Response0.05 Hz- 150 HzCalibration Vol.

  • Availability: 16 In Stock
  • Min. Qty. Per Consignee: 1
  • Functional requirements: electricity (AC-powered) bedside device designed to continuously detect, measure, and display a patient's electrocardiogram (ECG) through leads and sensors attached to the patient, it also typically display heart rate. The device is typically equipped with audible and/or visual alarms that are triggered when the patient's parameters drop below or exceed pre-set limits. Continuous display of patient ECG and heart rate on screen,Allows display of single, 5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points.Operator can set audiovisual alarm levels for low or high heart rate.Operates from mains voltage or from internal rechargeable battery. - yes
  • Heart rate measurement range to be at least 30 to 250 bpm, with accuracy better than ± 5 bpm - yes
  • Heart rate trend display of at least previous 24 hours - yes
  • Audiovisual alarms required: high and low heart rate (operator variable settings), cardiac arrhythmia, sensor / wire disconnected, low battery - yes
  • weight - 1500 gram
Other Specifications Download Specification
GMDN Name And Code Multichannel Electrocardiographic , CT-1115
Functional Requirements: Electricity (AC-powered) Bedside Device Designed To Continuously Detect, Measure, And Display A Patient's Electrocardiogram (ECG) Through Leads And Sensors Attached To The Patient, It Also Typically Display Heart Rate. The Device Is Typically Equipped With Audible And/or Visual Alarms That Are Triggered When The Patient's Parameters Drop Below Or Exceed Pre-set Limits. Continuous Display Of Patient ECG And Heart Rate On Screen,Allows Display Of Single, 5 Lead ECG Or Simultaneous Display Of At Least 5 Waves Selected From Up To 12 Points.Operator Can Set Audiovisual Alarm Levels For Low Or High Heart Rate.Operates From Mains Voltage Or From Internal Rechargeable Battery. yes
Heart Rate Measurement Range To Be At Least 30 To 250 Bpm, With Accuracy Better Than ± 5 Bpm yes
Heart Rate Trend Display Of At Least Previous 24 Hours yes
Arrhythmia Detection Facility Required; Minimum Gradation Of 1 Bpm yes
Audiovisual Alarms Required: High And Low Heart Rate (operator Variable Settings), Cardiac Arrhythmia, Sensor / Wire Disconnected, Low Battery yes
User's Interface manual
In Built Software And/or Standard Of Communication yes
Weight 1500 gram
Mobility, Portability Protective splashproof case for clean storage and safe transport
Display Must Allow Easy Viewing In All Ambient Light Levels yes
Noise Lavel 50 dba
Heat Dissipiation: Should Maitain Nominal Temp And The Heat Should Be Disbursed Through A Exhaust Cooling Fan yes
Power Input And Frequency 220 to 240V, 50 Hz
Power Consumption 100V-240 VAC, 50Hz-60Hz, 70VAC watt
Power Cable Length 3 meter meter
Electrical Protection Provided By Fuses In Both Live And Neutral Supply Lines. yes
"Operating Condition:Capable Of Operating Continuously In Ambient Temperature Of 0 To 50 Deg C And Relative Humidity Of 15 To 90% In Ideal Circumstances" yes
"STANDARDS AND SAFETY:FDA / CE Approved Product; Manufacturer / Supplier Should Have ISO 13485 Certificate For Quality Standard. Electrical Safety Conforms To Standards For Electrical Safety IEC-60601-1 Shall Meet IEC-60601-1-2 (General Requirements For Safety - Electromagnetic Compatibility) And IEC 60601-2-25 (essential Performance Of Electrocardiographs)" yes
Warranty 3 years warranty & one year with min. 3 free servicing. years
Others: List Of Important Spare Parts And Accessories With Their Part Number And Costing. Certificate Of Callibration And Inspection To Be Provided yes

Price Dekho Price Dekho Price List in india