Three Phase Power Quality and Energy Analyzer, Advanced power quality functions, unprecedented energy analysis capabilities,Highest safety rating in the industry 600 V CAT IV/1000 V CAT III rated for use at the service entrance,Power Wave data capture,Power inverter efficiency,Energy monetization,Energy assessment,Frontline troubleshooting,Predictive maintenance,Long-term analysis,Load studies,Measure all three phases and neutral With included four flexible current probes with enhanced thin flex design to fit into the tightest places.Automatic Trending Every measurement is always automatically recorded, without any set-up.Logger function Configure for any test condition with memory for up to 600 parameters at user defined intervals.View graphs and generate reports With included analysis software,Battery life Seven hours,Wireless data download, Warranty-Three Years, Energy Loss Calculator..
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Three phase |
Display Type | LCD Backlit |
Display Mode | 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD |
Number Of Current Channels | 4 Nos. |
Number Of Voltage Channels | 5 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | 1 V to 1000 V Volts Volts |
Measurable Voltage Accuracy | ± 0.1 % |
Measurable Voltage Resolution | 0.01 Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 0.5 A to 6000 A Ampere |
Measurable Current Accuracy | ± 0.5 % ± 5 counts |
Measurable Current Resolution | 0.5 A to 600 A -- 0.1 A & 5A to 6000A --- 1A Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 6000000 KW |
Power Accuracy | ± 1 % ± 10 counts |
Power Resolution | 0.1 W to 1MW Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | 42.500 Hz to 69.000 Hz Hz Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | ± 2.5 % |
Resolution In Measurement Of Total Harmonics Distortion | 0.1% |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | 1 to 50 Grouping |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | ± 0.1 % |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | NA |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | ± 0.1 % |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | 1.0 > 2.8 |
Measurable Crest Factor Accuracy | ± 5 % |
Measurable Crest Factor Resolution | 0.01 |
Screen Memory | Available |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | 8000 MB |
Type Of Battery Used | LITHIUM ION |
Battery Backup | 8 Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 200 Grams |
Dimensions(LXWXH) | 265 x 190 x 70 cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | 0 °C ~ +40 °C; 0 °C ~ +50 °C excluding battery degree celsius |
Operating Humidity | +10 °C ~ +30 °C: 95 % RH non-condensing, +30 °C ~ +40 ~ +50 °C: 45 % RH non-condensing % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | AVAILABLE |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | CAT-III 1000V,CAT-1V 600V |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | 10100 |
TTC Report Date | 03/09/2017 |
Name Of Lab | FLUKE |
Address Of Lab | FLUKE USA |
Interface | USB |