Bring home the amazing Luminous UPS power Supply and never again worry about losing power again. UPS stands for uninterruptible power supply. The Luminous UPS provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery runtime of this UPS supply is comparatively high, making sure you do not lose any data when the power goes out as it starts immediately. When power loss occurs, the rectifier simply drops out of the circuit and the batteries keep the power steady and unchanged. When power is restored, the rectifier resumes carrying most of the load and begins charging the batteries, though the charging current may be limited to prevent the high-power rectifier from overheating the batteries and boiling off.
Other Specifications Download Specification | |
---|---|
Rating In KVA/ Min VAH Capacity Of Battery | 1.0/168 KVA/VAH |
Technology | MOSFET-PWM |
Input | Single phase sinewave(160-280v) Volt |
Rated Output | Single phase sinewave 230v AC , 50Hz Volt |
Load Power Factor | 0.6 |
Variation In AVR Output In AC Mode | 9 % |
Variation In Output Voltage In Battery Mode | 1 % |
Variation On Output Frequency In Battery Mode | 0.5 Hz |
Inverter Efficiency | 70 % |
Total Harmonic Distorsion | 40 % |
Switching Over Time | 10 Mili sec |
Overload | 10 % |
Overload Time | 10 Minutes |
Protection Against Short Circuit Of UPS | Yes |
Protection For Outside Input Voltage Range | 280 Volt |
Protection Against Discharge Per 12v Battery | 10.5 Volt |
Degree Of Protection | IP-21 |
Type Of Battery | Tubular confirming to IS:13369 |
Type Of Enclosure | Mild steel |
Dry Heat Test At 45 Degree For 16 Hrs As Per IS:9000 Pt-3/sec-5 | Yes |
Damp Heat Test At 45 Degree , RH -95% For 2-cycle As Per IS:9000 Pt-5/sec-1 | Yes |
Cold Test As Per IS:9000 Pt-2/sec-4 | Yes |
Availability Of The Type Test Report From Central Govt./NABL/ILAC Accredited Lab | Yes |
Type Test Certificate No. And Date | R-96000159 03.09.2017 |
Name Of Lab | MR. MOHAN CHANDRA BHATT |
Address Of Lab | rIT-m, VILLAGE- DEV NAGAR, NEAR SHIV WARI,P.O- GAGRET, TEHSIL MB, DlSTT. UNA 177201,HIMACHAL PRADESH, INDIA |