× All the transactions performed on 2.0 is available here. To access Market click "Home".

oscilloscope (gp)(osc30)

` 38,475.00

  • Offered Price: ` 40500.00
  • MRP: `45000.00

oscilloscope dual trace 30 MHZ.

  • Availability: 25 In Stock
  • Min. Qty. Per Consignee: 1
  • Operating System - Non -Windows
  • Bandwidth Upgradability - No
  • No. of Analog Channels - 2 Number
  • No. of Digital Channels - 8 Number
  • Min. Detectable Pulse Width - NA ns
Other Specifications Download Specification
Type Digital
Operating System Non -Windows
Bandwidth Upgradability No
No. Of Analog Channels 2 Number
Digital Channels Yes
No. Of Digital Channels 8 Number
Record Length Per Digital Channel Simultaneously NA GS/sec
Sampling Rate Per Digital Channel Simultaneously NA Mega Points
Min. Detectable Pulse Width NA ns
Memory Upgradability No
Segmented Memory Feature Availability Yes
Vertical Sensitivity 500mV per Div to 10 V/div
Vertical Resolution 8 bits
Coupling AC, DC, Ground
Time Base Range 1 ns/div to 100 s/div
Trigger Types Edge, Slope, Pulse, Video, Window, Dropout, Runt, Pattern
Measurements 38 Types of Automatic Measurements of Time, Voltage and Delay. Math Function - Add, subtract, multiply, divide, FFT , Integration, Differentiation
Frequency Analysis Feature Yes
In-built Frequency Counter Yes
In-built Function Generator No
Acquisition Modes Auto, Normal, Peak detect, Average
Display Type Monochrome
Display Size 17.8 CM
I/O Interface USB Host, USB Device, LAN, Pass / Fail, Trigger Out
Standard Accessories To Be Supplied 2 nos. Passive Probe, Quick Start, Power Cord, USB Cable, Certificate
Operating Temperature Range 10 deg C to 40 deg C Degree C Degree C Degree C
Operating Humidity (RH) 85% % %
Power Supply 230V +- 10% , 50Hz
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration yes
Test Report No. 1546
Test Report Date 26/10/2017
Name Of The Lab QMS CERTIFICATION
Warranty 1 Year
Real Time Bandwidth 20 MHz
Record Length Per Analog Channel Simultaneously NA GS/sec Mega Point
Sample Rate Per Analog Channel Simultaneously NA GS/sec
Waveform Update Rate NA Waveforms/
Time Base Accuracy 0.05 PPM

Price Dekho Price Dekho Price List in india