× All the transactions performed on 2.0 is available here. To access Market click "Home".

ul approved trms digital multimeter with pc interface (kusam-meco)(km 859cfs)

` 21,235.00

  • MRP: `23595.00

5-4/5 Digit 50,000/500,000 Counts Autoranging Digital Multimeter with Temp. measurement..

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 5
  • Display - 4.5 Digit
  • Measurement Type - True RMS
  • Count - 200000
  • AC Voltage Measurement Accuracy - 0.5 %
  • AC Current Measurement - 10 Ampere
Other Specifications Download Specification
Type Hand Held
Display 4.5 Digit
Measurement Type True RMS
Count 200000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.5 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.5 %
AC Current Measurement 10 Ampere
AC Current Measurement Accuracy 0.5 %
DC Current Measurement 10 Ampere
DC Current Measurement Accuracy 0.5 %
Resistance Measurement 40 Mega Ohm
Resistance Measurement Accuracy 0.06 %
Frequency Measurement 50 Kilo Hertz
Frequency Measurement Accuracy 0.1 %
Capacitance Mreasurement Range .01 to 1000 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement -50 to 1000 Degree C
Temperature Measurement Accuracy 1.5 %
Feature Of Continuity Test And Diode Test Available
Feature Of Data Logging Available
If Data Logging Feature Is Available, Internal Memory min. 5000 points 200 readings
Computer Interface Alongwith Software Available
True RMS AC Voltage Band Width 100
Safety Rating Category IV 600 V of IEC 61010
Overload Protection Through Fuse
Operating Temperature Range 0 degree to 45 degree
Operating Humidity (RH) 80%
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
If Battery Operated, Type And No. Of Battery Single Alkaline 9V Battery
Total Voltage Of Battery 9V
Standard Accessories Supplied With The Equipment Test Lead Pair, Holster,Battery installed,usermanual,carryingcase,BKP60banana Plug type-K Thermocouple
Dimensions (H X W X L) 198x97x55 mm x mm x
Weight 500 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 0611307
Test Report Date 6/11/17
Name Of The Lab Kusam-Meco
Warranty 1 Year

Price Dekho Price Dekho Price List in india