1kva pure sine wave offline ups (uniline)(1kva24v p2k-13g-628-B)

` 14,256.65

  • Offered Price: ` 15007.00
  • MRP: `16675.00

1KVA Pure Sine Wave Offline UPS 624VAH/800Watt comes with lots of advanced features. The UPS AC input voltage is 140V to 280V. The inverter efficiency DC to AC80. The input frequency range of this Uniline UPS is 50Hz /- 6. The output voltage range is 220V /- 9 main mode, 220V /- 5 battery mode. The output frequency range is same as input under main mode and 50Hz /- 1 under battery mode. The model comes with external battery. The external battery used here is a 2 x 12 V 26AH. The external battery charging current option is up to 20 Amps. The maximum charging voltage is 27.6 V. Recharge time required is 3 to 4 hours 90. The model has a cold start facility as well there by the UPS can be started during power failure. 1KVA UPS has indications , load on AC, load on DC, overload/ low, battery trip, AC on, DC on, battery level and load level graph..

  • Availability: 1,000 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - MOSFET-PWM
  • Input - Single phase sinewave(160-280v) Volt
  • Rated Output - Single phase sinewave 230v AC , 50Hz Volt
  • variation in AVR output in AC mode - 9 %
  • Inverter Efficiency - 90 %
Other Specifications Download Specification
Rating In KVA/ Min VAH Capacity Of Battery 1.0/800 KVA/VAH
Technology MOSFET-PWM
Input Single phase sinewave(160-280v) Volt
Rated Output Single phase sinewave 230v AC , 50Hz Volt
Load Power Factor .8
Variation In AVR Output In AC Mode 9 %
Variation In Output Voltage In Battery Mode 1 %
Variation On Output Frequency In Battery Mode .5 Hz
Inverter Efficiency 90 %
Total Harmonic Distorsion 3 %
Switching Over Time 2 Mili sec
Overload 10 %
Overload Time 10 Minutes
Protection Against Short Circuit Of UPS Yes
Protection For Outside Input Voltage Range 280 Volt
Protection Against Discharge Per 12v Battery 10.5 Volt
Degree Of Protection IP-21
Type Of Battery SMF-VRLA confirming to JISC-8702 Pt 1,2 &3
Type Of Enclosure Mild steel
Dry Heat Test At 45 Degree For 16 Hrs As Per IS:9000 Pt-3/sec-5 Yes
Damp Heat Test At 45 Degree , RH -95% For 2-cycle As Per IS:9000 Pt-5/sec-1 Yes
Cold Test As Per IS:9000 Pt-2/sec-4 Yes
Availability Of The Type Test Report From Central Govt./NABL/ILAC Accredited Lab Yes
Type Test Certificate No. And Date 2727/ 4.12.2009
Name Of Lab ETDC
Address Of Lab AMBALA CANTT