Scientech 801C EasyScope Is New Trend Analog Oscilloscope With Digital Touch. The Digital Readout Backlit Color LCD Displays Volt Per Div And Time Per Div Settings. Rugged, Light Weight, Sharp And Bright Trace. The Vertical Bandwidth Is More Adequate For All Your Needs And You Can Easily View Signal Upto 40MHz. A Built-In Component Tester Makes It An Indispensable Instrument, As This Allows Testing Of Both Passive And Active Components. For More Detail Please Refer Scientech 801C Datasheet. Offered Price Is Inclusive GST @18 Percent. Delivery Period 45 Days..
Other Specifications Download Specification | |
---|---|
Type | Analog |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 2 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | No |
Vertical Sensitivity | 2mV/Div to 5 V/Div |
Vertical Resolution | NA bits |
Coupling | AC, DC, Ground |
Time Base Range | 0.5 Micro Second To 0.2 Second |
Trigger Types | Automatic And Normal |
Measurements | NA |
Frequency Analysis Feature | No |
In-built Frequency Counter | No |
In-built Function Generator | No |
Acquisition Modes | NA |
Display Type | Monochrome |
Display Size | 8 X 10 Cm CM |
I/O Interface | NA |
Standard Accessories To Be Supplied | BNC To Crocodile Cable , BNC To Test Prod Cable, Power Cord, Test Prod Lead |
Operating Temperature Range | 0 to 40 degree C Degree C |
Operating Humidity (RH) | 80% RH % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | NSICGPIND20140009211 |
Test Report Date | 10.06.2016 |
Name Of The Lab | NSIC Indore |
Warranty | 3 Year |
Real Time Bandwidth | 30 MHz |
Record Length Per Analog Channel Simultaneously | NA Mega Point |
Sample Rate Per Analog Channel Simultaneously | NA GS/sec |
Waveform Update Rate | NA Waveforms/ |
Time Base Accuracy | 0.05 PPM |