VSP G400 Unified - SAN/NAS with 128GB Cache, 8 x 16Gbps FC Ports for Block, 8 x 10Gbps NAS Ports, 100TB Usable Capacity using SAS Drives, Heterogeneous Storage Virtualization, Snapshots, Clones and Remote Replication Licenses included..
Other Specifications Download Specification | |
---|---|
Type Of Storage | Unified |
Usable Capacity Of Storage System | 100 TB |
Hardware Form Factor Of Unified/NAS System | 15 RU |
Type Of Drives | SAS |
RAID Available | Yes |
If Yes ,RAID Type | 6 |
Type Of Front End Ports | 8 |
Number Of Front End Port | 8 |
Speed Of Front End Ports In Gbps | 16Gbps FC abd 10Gbps IP Gbps |
Type Of Back End Ports | SAS |
Number Of Back End Port | 4 |
Speed Of Back End Ports In Gbps | 12 Gbps |
Number Of Controllers Available In Storage System | 2 |
Supported Global Cache | Yes |
Total Configurable Cache Per Controller. | 128 GB |
Total No Of Drive Slots In The Storage System | 96 |
No Drive Slots Populated In The Storage System | 91 |
Capacity Of Single Drive Populated With The Storage System | 1800 GB |
No Of Drive Slot Available For Scalability | 389 |
No Of Snap Shot Copies | 100000 |
Remote Replication | Yes |
Synchronous Replocation Support | Yes |
Asynchronous Replication Support | Yes |
No Of Volume Supported | 4096 |
Three Way DR Capability | No |
Protocols Supported By The Storage From Day One Such As NFS,CISF,FC , ISCSI | FC, NFS and CIFS/SMB |
Hot Spare Available | Yes |
If Yes ,No Of Drives Per Hot Spare | 30 |
No Single Point Of Failure (SPOF) With Support For Non Disruptive Replacement Of Hardware Components | Yes |
The Storage Provides Non-disruptive Firmware/micro Code Upgrade, Device Reallocation And Configuration Changes. Storage Architecture Allow New Microcode/Firmware. | Yes |
Network Switch | Not Available |
If Available, Tpye Of Network Switch (@10Gbps Min) | NA |
Hardware Form Factor Of Network Switch | NA RU |
Number Of Network Switches Provided With Storage System | NA |
Number Of Active Ports In The Network Switch | NA |
Operating System Platforms Supported | NA |
Clustering Supported | No |
Deduplication | Yes |
Compression | Yes |
Operating Temp Range | 10 to 40 degrees Degree C |
Storage Temp Range | 10 to 40 degrees Degree C |
Operating Humidity (Rh) | 8 to 80 % |
Storage Humidity (Rh) | 8 to 80 % |
BIS Registration Under CRS Of MeiTY | Yes |
BIS Regirstration No. ( Shall Be Furnished When Demaded By The Buyer) | CRS2016-2147/R-41046221 |
Storage System Is Compliant With IPv6 | Yes |
Standby Power Consumption Of System | 3.5KW Watt |
Max Power Consumption Of System | 4.5KW Watt |
Scope Of Supply | It includes installation, commissioning & integration togather with all necessary software to make the system fully functional as intended. |
Warranty | 3 Year |
Type Of Clustering | NA |