× All the transactions performed on 2.0 is available here. To access Market click "Home".

medical x ray film---6. 5 inch x 8.5 inch 16.5 cm x 21.6 cm ---50 sheet packet--- blue sensitive (retina brand)(medical x ray film---6 5 inch x 85 inch)

` 830.00

  • MRP: `1100.00

MEDICAL X-RAY FILMS USED FOR MEDICAL RADIOGRAPHY ----PACKET OF 50 SHEETS polyester base.

  • Availability: 500 In Stock
  • Min. Qty. Per Consignee: 50
  • The assembly made up of material non corrosive - Yes
  • Length of Machine - 6.5 inch*8.5 inch
  • Width of Machine - 6.5 inch*8.5 inch
  • Weight (Empty) - 2 kg
  • Auto washer - Yes
Other Specifications Download Specification
Table Top Automatic Medical X Ray Film Processor Machine Yes
The Assembly Made Up Of Material Non Corrosive Yes
Length Of Machine 6.5 inch*8.5 inch
Width Of Machine 6.5 inch*8.5 inch
Height Of Machine 6.5 inch*8.5 inch
Weight (Empty) 2 kg
Auto Developer , Yes
Auto Fixer Yes
Auto Washer Yes
Auto Dryer Yes
Material Of Cabinet ABS Plastic
Rollers Mechanism Motrised
Rollers Material PVC with inner pipes of SS-304 Grade
Minimum Film Size Length X Width 100 x 100
Maximum Film Size Length X Width 356 x 432
Continious Film Roller Transport And Auto Start And Stop Facility Rigid PVC
Processing Time: 90 Sec To 200 Sec In Steps Of Six Second With LED Display Yes
Processing Capacity Of Size 356mm X 432 Mm In 90 Second Mode Yes
Minimum Capacity Of Fixer,Washer And Developer Tank 5
Mimimum Capacity Of Replenishment Developer And Fixer Tank With Overflow Drain Facility 25
Automatic Replenishment Yes
Developer And Fixer Temprature Adjustable Throught Automatic Temprature Controller Yes
Operating Temp Range (28-37 )degree degree
Dryer Temprature(maximum) 70 degree
Power Supply 230 volt A.C
Maximum Power Consumption 1.4 kwh
Water Filter Compatible With Equipment Supplied With Equipment Yes
Manual ,auto Stop With Power Saver/standby Mode Facility Yes
High Voltage Test 1.5 KV For I Minute Yes
Minimum Insulation At 500 V DC yes
Instruction Manual Supplied With Equipment yes
Chemicals/Materail For Running Equipment For Minimum One Month yes
Radiology Certificate For Processed Film yes
Availibility Of Type Test Report For Performance Test yes
Test Report To Shown To Buyer As And When Required Yes
Test Report Number & Date RLPL28694 ---29.05.2016
Name & Address Of Laboratory RANDOX LABORATORIES (I) PVT. LIMITED 3RD FLOOR, GODREJ COLISEUM SOMAIYA HOSPITAL ROAD, 077 EASTERN EXPRESS HIGHWAY, BEHIND EVERARD NAGAR, SION (EAST), Mumbai, Maharashtra, 400022, India
Certifiacation iso-9001;2008

Price Dekho Price Dekho Price List in india