× All the transactions performed on 2.0 is available here. To access Market click "Home".

uv-vis spectrophotometer 190-1000nm (lark)(liuv1500)

` 170,000.00

  • MRP: `200000.00

SPECTROPHOTOMETER-UV1500Model,Optical System Single Beam Grating1200 Lines/mm Wavelength Range 190-1000nm, Bandwidth 2 nm, Wavelength Accuracy 1nmWavelength Repeatability 0.5nm, Wavelength Setting Auto,Photometric Accuracy 0.5TPhotometric Repeatabiltiy 0.3T,Photometric Range -0.3-3A,0-200T,Stray Light 0.3T Stability 0.002A/h @500nm,Display 128 x 64 Dots LCD,Detector Silicon PhotodiodeStandar Cell Holder 4-position 10mm cell changer,Light Source Tungsten Deuterium LampOutput USB Port Parallel Port Printer,Power Requirements AC 85250VDimesnion 420 x 280 x 180mm, Weight 15kg.

  • Availability: 2 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC
  • Monochromator - Concave holographic grating with 1200 lines/mm
  • Wavelength Range (user selectable) - 340-960 nm
  • Wavelength Accuracy - +-1 nm
  • Type of Detector - Photodiode
Other Specifications Download Specification
Spectrophotometer Type Microprocessor Based
Display High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC
Monochromator Concave holographic grating with 1200 lines/mm
Wavelength Range (user Selectable) 340-960 nm
Wavelength Resolution 0.2 nm
Wavelength Accuracy +-1 nm
Repeatability +-1 nm
Spectral Bandwidth < 2
Type Of Detector Photodiode
Measuring Modes Transmittance (T), Absorbance (ABS), Concentration (CONC) by K Factor and Multi standards.
Operating Mode Single wavelength: Measuring 1, ABS and CONC
Light Source Tungstan Halogen Lamp
Power 230 V +- 10 50Hz
Standard Accessories To Be Supplied 10 nm path length four (4 nos.) Cuvettes matched with 3 percent
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " yes
Power Requirements 230 V +- 10, 50 Hz
Operating Temperature 30 Degree C
Operating Humidity (RH) 70 %
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" NA
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) NA
Test Report No. NA
Test Report Date NA
Name Of The Lab NA
Warranty 1 Year

Price Dekho Price Dekho Price List in india