Keysight U1194A 600 A AC-DC, 600 Volt AC-DC, True RMS clamp meter count 6000 true RMS current measurement clamp meter fit comfortably in the palm of your hand and allow you to select measurement functions with thumb press. AC Current Measurement Range Ampere, Unique wire separator to separate wires from a bundle - for improved visibility when making measurements, these clamp meters come with integrated LED flashlight that illuminates the test area. These features ensure that you are better equipped when making measurements, Vsense to perform non-contact voltage detection, Visual and audible continuity indication in noisy environments, Digital Multimeter DMM with resistance, capacitance, DCV, ACV, DCA, ACA, DCA and ACA, Temperature measurement, CAT III 600 V / CAT IV 300 V safety rating. Standard 3 year warranty. Refer Keysight datasheet for detailed specifications. Prices including GST @18 percent. Standard delivery period 60 days...
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | Backlit |
Measurement Type | True RMS |
AC Current Measurement Range | 0 to 999.9 Ampere |
AC Current Measurement Accuracy | + or - 2 % |
AC Voltage Measurement Range | 0 to 1000 Volt |
AC Voltage Measurement Accuracy Upto 600 Volts | + or - 1 % |
AC Voltage Measurement Accuracy Beyond 600 Volts | + or - 1.5 % |
Inrush Current (Integration Time) | 100 millisecon |
DC Current Measurement Range | 0 to 999.9 Ampere |
DC Current Measurement Accuracy | + or - 2 % |
DC Voltage Measurement Range | 1000 Volt |
DC Voltage Measurement Accuracy | + or - 1 % |
Resistance Measurement Range | 0 to 4000 Ohm |
Resistance Measurement Accuracy | + or - 1.5 % |
Continuity | < or = 30 Ohm |
Frequency Measurement Range | 10 to 400 |
Frequency Measurement Accuracy | + or - 0.5 |
Jaw Size (Dia In Closed State) | 35 mm |
Satety Rating | Category III 600 V of IEC 61010 -2-D31 |
Operating Temperature Range | –10 to 50 °C Degree C Degree C |
Operating Humidity (RH) | 0 to 80% RH % % |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
Standard Accessories Supplied With The Equipment | Certificate of calibration, Quick Start Guide, K-type thermocouple, 1.5V AAA Alkaline battery, Soft carrying case, test lead with 4-mm tips |
Dimensions (H X W X L) | 77.1 x 238.0 x 38.6 mm mm x mm x |
Weight | 348g gms gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | U1194ATW56450064 |
Test Report Date | 22-MAR-2017 |
Name Of The Lab | Keysight Technologies Malaysia |
Warranty | 3 Year |