Keysight U1213A-1000A AC-DC 1000 Volts AC-DC, Ture RMS Handheld Clamp Meter enable high-current measurements without breaking the circuit. Clamp meters unlike most clamp meters, - to simplify troubleshooting during installation and maintenance. Best of all, they provide an extra layer of protection with CAT IV 600V and CAT III 1000 V safety ratings. Features Large clamp opening of 52 mm or 2 inches Optional Bluetooth wireless connectivity using U1177A Infrared IR-to-Bluetooth Adapter. Includes full-featured DMM with resistance, capacitance, frequency and temperature functions. High resolution measurements. Measure current as low as 0.01 mA, Peak hold, Dual ranging mode, manual and auto, Large dual display, Min/max recording capability. Standard 3 year warranty. Refer Keysight datasheet for detailed specifications. Prices including GST @18 percent. Standard delivery period 60 days...
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | Backlit |
Measurement Type | True RMS |
AC Current Measurement Range | 0 to 999.9 Ampere |
AC Current Measurement Accuracy | + or - 2 % |
AC Voltage Measurement Range | 0 to 1000 Volt |
AC Voltage Measurement Accuracy Upto 600 Volts | + or - 1 % |
AC Voltage Measurement Accuracy Beyond 600 Volts | + or - 1.5 % |
Inrush Current (Integration Time) | 100 millisecon |
DC Current Measurement Range | 0 to 999.9 Ampere |
DC Current Measurement Accuracy | + or - 2 % |
DC Voltage Measurement Range | 1000 Volt |
DC Voltage Measurement Accuracy | + or - 1 % |
Resistance Measurement Range | 0 to 4000 Ohm |
Resistance Measurement Accuracy | + or - 1.5 % |
Continuity | < or = 30 Ohm |
Frequency Measurement Range | 10 to 400 |
Frequency Measurement Accuracy | + or - 0.5 |
Jaw Size (Dia In Closed State) | 2 inches |
Satety Rating | Category III 600 V of IEC 61010 -2-D31 |
Operating Temperature Range | –10 to 50 °C Degree C Degree C |
Operating Humidity (RH) | 0 to 80% RH % % |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
Standard Accessories Supplied With The Equipment | Test leads, 4-mm probes, soft carrying case, Quick Start Guide, Certificate of Calibration (CoC) |
Dimensions (H X W X L) | 106 mm (W) X 260 mm (L) X 43 mm (H) mm x mm x |
Weight | 525 grams with batteries included gms gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | U1213AMY57171285 |
Test Report Date | 08-AUG-2017 |
Name Of The Lab | Keysight Technologies Malaysia |
Warranty | 3 Year |