Availability Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS power overload or fault. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Scalable runtime Allows additional run time to be quickly added as needed. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.Manageability SmartSlot Customize UPS capabilities with management cards. LED status indicators Quickly understand unit and power status with visual indicators. Serial connectivity Provides management of the UPS.
Other Specifications Download Specification | |
---|---|
Rating In KVA | 10 KVA |
Technology | IGBT-PWM without inbuilt isolation transformer |
Input Power | single phase 160V - 260V sinewave,50Hz |
Output Power | single phase 230V ±1% sinewave,50Hz |
Backup Time | 90 Minutes |
Minimum VAH | 19200 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | No (only for IGBT-PWM Technology) |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | 2 % |
Overall Efficiency | 92 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | Without |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | NTS/PPTL/UPS-310/05 |
Type Test Certificate Date | 09/10/2015 |
Name Of Lab | NISAKI TECHNOLOGY SERVICES |
Address Of Lab | BANGALORE |
Supply & Commissioning | YES |
Warranty | 2 Years |