× All the transactions performed on 2.0 is available here. To access Market click "Home".

Keysight N5173B-520 RF Signal Generator 20 GHz (Keysight Technologies)(N5173B with option 520, 1E1, UNT)

` 2,290,981.00

  • MRP: `2670771.00

The N5173B -520 EXG analog is a cost-effective choice when system creators need to balance budget and performance. Offering the best combination of output power 20 dBm at 20 GHz with option 1EA and low harmonics -55 dBc, the EXG is well-suited to the characterization of broadband microwave components such as filters and amplifiers. It also supports continuous-wave CW blocking for receiver testing or basic local-oscillator upconversion for point-to-point microwave backhaul links. The offered configuration is with option 520-20GHz frequency, Step Attenuator 1E1 and Analog Modulation option UNT.To reduce cost of ownership EXG signal generators are designed for reliability and fast, easy calibration, service and repair. The recommended three-year calibration cycle and self-maintenance strategy help reduce support costs and increase instrument uptime. Standard 3 Year warranty. Refer Keysight datasheet for detailed specifications. Prices indicated including GST@18 percent.Std delivery 60days.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Frequency Range - 10 MHz to 20 GHz
  • Frequency Resolution - 0,1 Hz
  • Ageing Rate for reference frequency (As declared by OEM) - Less than 1 PPM/Year
  • SSB Phase Noise at 1GHz,on 20KHz offset (dBc/Hz) - less than -105 dBc
  • Non Harmonics (>50 KHz carrier offset) - NA dBc
Other Specifications Download Specification
Type RF Signal Generator
Frequency Range 10 MHz to 20 GHz
Frequency Resolution 0,1 Hz
Ageing Rate For Reference Frequency (As Declared By OEM) Less than 1 PPM/Year
Temperature Stability For Reference Frequency Less than 1 PPM
SSB Phase Noise At 1GHz,on 20KHz Offset (dBc/Hz) less than -105 dBc
Harmonics At 3 GHz Level At 0 DBm less than -30 dBc
Non Harmonics (>10 KHz Carrier Offset) less than -50 dBc
Non Harmonics (>50 KHz Carrier Offset) NA dBc
Reverse Power Protection 0.5 W, 0 Vdc Watt Watt
Minimum Output Level -120 dBm
Maximum Output Level +13 dBm
Output Level Resolution 0,1 dB
Total Accuracy Forall Specified Output Level At 25 Degree C In Continuous Wave Mode ± 0.9 dB dB dB
VSWR On All Operating Frequencies 1.8
Memory (Minimum Storage Settings) 1000
Amplitude Modulation (AM) Operating Modes Internal & External
Minimum Amplitude Modulation Frequency (3 DB), F > 100 KHz DC/10 Hz Hz
Maximum Amplitude Modulation Frequency (3 DB), F > 100 KHz 100 kHz KHz
Modulation Depth 0 to 100% %
Resolution Of AM 0.1%
AM Distortion At 1 KHz < 1.5% of setting +1%
Frequency Modulation (FM) Operating Modes Internal & External
Minimum Frequency Modulation Frequency (-3 DB) Standard DC/1 Hz
Maximum Frequency Modulation Frequency (-3 DB) Standard 7 MHz
Minimum Frequency Deviation 2.5MHz
Maximum Frequency Deviation 160MHz KHz
Resolution Of FM 0.025% of deviation or 1 Hz
Setting Error (at AF=1 KHz And 50% Max. Deviation) For FM < ± 2% + 20 Hz
Phase Modulation Available
If Available, Phase Modulation Operatinf Mode Internal & External
Minimum Phase Deviation 1.25 Radians Radians Radians
Maximum Phase Deviation 80 Radians Radians Radians
Resolution Of Phase Modulation 1 %
Setting Error (at AF=1 KHz) For Phase Modulation < 0.2% (typ)
Internal Modulation Generator For AM/FM/PM 0.1 Hz to 2 MHz tunable to 3 MHz with resolution of 0.1 Hz
Pulse Modulation Not-Available
If Available, Pulse Modulation Operating Modes NA
Rise And Fall Time NA ns
On/Off Ratio NA dB
Minimum Pulse Width NA ns
Input Level NA
RF Digital Sweep Range And Width 9KHz to 20GHz
RF Digital Sweep Time Range 100 μs to 100s
RF Analog Sweep Not-Available
If Available, RF Analog Sweep Range And Width NA
RF Analog Sweep Time Range NA
Pulse Generator Not-Available
If Available, Pulse Generator Operating Mode NA
Pulse Width NA
Pulse Delay NA
Pulse Period NA
Vector Modulation Not-Available
Internal Base Band Generator Bandwidth NA MHz
Arbitory Waveform Memory NA Mega samples
Modulation NA
Error Vector Magnitude (EVM) 0 %
Phase Modulator Not-Available
If Available, Range Of Modulating Signal (Wide Mode) NA
If Available, Range Of Modulating Signal (Narrow Mode) NA
Interface Available GPIB IEEE-488.2, 1987 with listen and talk LAN 1000BaseT LAN interface, LXI Class C compliant, USB Version 2.0
Standard Acessories (To Be Supplied) Country-specific power cord, Documentation set (CD-ROM), 3-year return-to-Keysight warranty
Power Requirements 230 V +/-10% AC, 50 Hz +/- 3%
Operating Temperature Range 0 to 55 Degree C Degree C Degree C
Operating Humidity (RH) Yes %
"Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 45 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) All The Functional Paramteres Are To Be Verified Before And After Recovery Period Of 1 Hours Of Above Environmental Test Sequence As Above. There Shall Be No Deterioration In Functional Parameters. Yes
Test Report No. 4216209-5081960-1
Test Report Date 09-DEC-2016
Name Of The Lab Keysight Technologies Malaysia
Warranty 3 Years

Price Dekho Price Dekho Price List in india