1. Earth resistance measurement 2. 2-pole and 3-pole measurements. 3. Reliable measurement results also at presence of stray currents. 4. Outstanding repeatability of measurement results also in case of high test probe resistance at various earthing structures e.g. asphalt, sand, stone. 5. Warnings for out of limits results and incorrect test conditions. 6. Auto power-off...
Other Specifications Download Specification | |
---|---|
Display Type | 3½ digit LCD display |
Measurable Earth Resistance Range | Auto ranging |
2-pole Method For Resistance Measurement | YES |
3-pole Method For Resistance Measurement | NO |
4-pole Method For Resistance Measurement | YES |
Number Of The Stakes | 2 NOS. |
Material Of The Stakes | GI |
Length Of The Stakes | 12 Inch cm |
Diameter Of The Stakes | 15 mm cm |
Number Of The Test Leads | 3 Nos. |
Length Of The Test Leads | 1. Test Lead 4.5 m Black 2. Test Lead 15 m Red 3. Test Lead 20 m Blue cm |
No. Of Test Leads With Clamps | N/A Nos. |
Length Of Test Leads With Clamps | N/A cm |
Measuring Range1 For Earth Resistance | 0.00 - 19.99 Ohms |
Measuring Range2 For Earth Resistance | 20.0 -199.9 Ohms |
Measuring Range3 For Earth Resistance | 200 - 999 Ohms |
Measuring Range4 For Earth Resistance | 1.000 k - 1.999 k Ohms |
Measuring Range5 For Earth Resistance | 2.00 k - 19.99 k Ohms |
Measuring Range6 For Earth Resistance | N/a Ohms |
Measuring Range7 For Earth Resistance | N/a Ohms |
Measurable Earth Resistance Resolution For Range1 | 0.01 Ohms |
Measurable Earth Resistance Resolution For Range2 | 0.1 Ohms |
Measurable Earth Resistance Resolution For Range3 | 1 Ohms |
Measurable Earth Resistance Resolution For Range4 | 1 Ohms |
Measurable Earth Resistance Resolution For Range5 | 10 Ohms |
Measurable Earth Resistance Resolution For Range6 | N/a Ohms |
Measurable Earth Resistance Resolution For Range7 | N/a Ohms |
Measurable Earth Resistance Accuracy For Range1 | ±(2 % of reading + 10 digits) ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range2 | ±(2 % of reading + 10 digits) ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range3 | ±(2 % of reading + 10 digits) ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range4 | ±(2 % of reading + 10 digits) ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range5 | ±(5 % of reading) ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range6 | N/a ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range7 | N/a ±% reading ± digits |
Stakeless Test(Clamp On) | no |
Facility To Measure Earth Voltage | Not Available |
If Yes,Measurable Earth Voltage Range | N/a Volts |
If Yes,Measurable Earth Voltage Accuracy | N/a % |
Minimum Open Circuit Output Voltage | 0 Volts |
Low Battery Indication | Available |
Over Range Indication | Available |
If Yes,Measurable Earth Voltage Resolution | N/a Volts |
Internal Memory | No |
Type Of Battery Used In The Power Supply | 1.5 V battery IEC LR14) |
Battery Backup Time | 0 Hours |
Battery Charger Provided With The Meter. | NA |
Weight Of The Tester | 410 grams |
Dimensions(LXWXH) | 280 x 70 x 80 mm cmXcmXcm |
Provision For External SD Card | No |
Interface | N/a |
Operating Temperature Range | 0 °C - 40 °C degree celsius |
Operating Humidity Range | 85 % RH (0 °C - 40 °C) % |
All Connecting Cables And Accessories To Be Supplied Along With The Tester. | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. | 1. Carrying Strap 2. Test Lead 4.5 m Black 3. Test Lead 15 m Red 4. Test Lead 20 m Blue 5. Earth Rod, 2 Pcs 6. Instrument Manual 7. Declaration of conformity 8. Declaration of Warranty |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. | Yes |
Type Test Report No. | MI2126 |
TTC Report Date | 10-07-2014 |
Name Of Lab | Metrel |
Address Of Lab | Slovenia Europe |