Single Cuvette Holder 10 mm, Bandwidth 1.0 nm, Double Beam 1200 Lines/mm Grating, Wavelength Range 190-1100 nm, Wavelength Accuracy 0.3 nm, Wavelength Repeatability 0.2 nm, Scanning Speed Fast, Medium and Low, Photometric Accuracy 0.3 percent T, Photometric Repeatability 0.2 percent T, Photometric Range -0.3-3A, 0-200 percent T, 0-9999C, Stability 0.001A/h @ 500 nm, Baseline Flatness 0.001A/h, Noise 0.001A/h, Data Output USB Port, Printer Parallel Port, 6 inches LCD display to show results and curves directly on the screen, Lamps D2 Lamp and Tungsten Halogen Lamp W Lamp, Lamp Selection enables conserving the life of D2 Tungsten lamps. Perfect Automatically Calibration System, Real time clock for date time stamping of results, Detector Silicon Photodiode, Power Supply AC 220V / 50Hz, Supplied with UV Analyst Multi functions Software, 10mm Glass Cuvette - 4 Nos., 10mm quartz cuvette - 2 Nos., Dust Cover.
Other Specifications Download Specification | |
---|---|
Spectrophotometer Type | Microprocessor Based |
Display | High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC |
Monochromator | Concave holographic grating with 1200 lines/mm |
Wavelength Range (user Selectable) | 340-960 nm |
Wavelength Resolution | 0.2 nm |
Wavelength Accuracy | +-1 nm |
Repeatability | +-1 nm |
Spectral Bandwidth | < 2 |
Type Of Detector | Photodiode |
Measuring Modes | Transmittance (T), Absorbance (ABS), Concentration (CONC) by K Factor and Multi standards. |
Operating Mode | Single wavelength: Measuring 1, ABS and CONC |
Light Source | Tungstan Halogen Lamp |
Power | 230 V +- 10 50Hz |
Standard Accessories To Be Supplied | 10 nm path length four (4 nos.) Cuvettes matched with 3 percent |
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " | As per OEM |
Power Requirements | 230 V +- 10, 50 Hz |
Operating Temperature | 28 DEGREE Degree C |
Operating Humidity (RH) | 60 % % |
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" | As per OEM |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) | As per OEM |
Test Report No. | As per OEM |
Test Report Date | As per OEM |
Name Of The Lab | As per OEM Chennai |
Warranty | 1 Year |