× All the transactions performed on 2.0 is available here. To access Market click "Home".

industrial grade digital multimeter model 603 (kusam-meco)(603)

` 1,695.00

  • MRP: `1885.00

3-1/2 Digit 1999 Counts Large LCD Display Digital Multimeter.

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 10
  • Display - 3.5 Digit
  • Measurement Type - Average
  • Count - 4000
  • AC Voltage Measurement Accuracy - 0.5 %
  • AC Current Measurement - 10 Ampere
Other Specifications Download Specification
Type Hand Held
Display 3.5 Digit
Measurement Type Average
Count 4000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.5 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.5 %
AC Current Measurement 10 Ampere
AC Current Measurement Accuracy 1.5 %
DC Current Measurement 10 Ampere
DC Current Measurement Accuracy 1.5 %
Resistance Measurement 100 Mega Ohm
Resistance Measurement Accuracy 1 %
Frequency Measurement 50 Kilo Hertz
Frequency Measurement Accuracy 0.1 %
Capacitance Mreasurement Range NA Micro Fara
Capacitance Measurement Accuracy NA %
Temperature Measurement NA Degree C
Temperature Measurement Accuracy NA %
Feature Of Continuity Test And Diode Test Available
Feature Of Data Logging Not Available
If Data Logging Feature Is Available, Internal Memory NA
Computer Interface Alongwith Software Not Available
True RMS AC Voltage Band Width NA
Safety Rating Category II 600 V of IEC 61010.
Overload Protection Through Fuse
Operating Temperature Range 0 degree to 50 degree
Operating Humidity (RH) 70%
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) CE
If Battery Operated, Type And No. Of Battery Single 9V Battery
Total Voltage Of Battery 9V
Standard Accessories Supplied With The Equipment Test Lead, Spare Fuse, Battery, User Manual, Carrying Case
Dimensions (H X W X L) 170x80x40 mm x mm x
Weight 250 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 2711328
Test Report Date 27-11-2017
Name Of The Lab Kusam-Meco
Warranty 1 Year

Price Dekho Price Dekho Price List in india