× All the transactions performed on 2.0 is available here. To access Market click "Home".

High Voltage MPPT Solar Charge Controller - 48 or 72 Volt - 50A Battery Charging through Solar Power (Systellar Innovations)(CC-MPPT-HV-50A-4872)

` 78,375.00

  • Offered Price: ` 82500.00
  • MRP: `95000.00

High Voltage Solar MPPT Shrage Controller having MPPT Operating Voltage Range of 53 - 600 VDC, Maximum PV Voltage is upto 750 VDC, Connected Battery Bank Voltage 48 Volt or 72 Volt Auto Select, for 48 Volt the maximum connected PV capacity is upto 3.3 Kwp and for 72 Volt the maximum connected PV capacity is upto 5.0 KWp..

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 1
  • Compatibility with battery type (User Selectable) - Lead acid & Tubular &VRLA-SMF
  • Battery/battery bank Voltage - 48 Volts
  • Capacity of the battery to be charged(User Selectable) - 25 to 200 Ah C10 at 48 VDC AH
  • Number Of Independent charging Stations - 1 Nos.
  • Efficiency - Upto 99 %
Other Specifications Download Specification
Charger Technology SMPS Based
Compatibility With Battery Type (User Selectable) Lead acid & Tubular &VRLA-SMF
Battery/battery Bank Voltage 48 Volts
Capacity Of The Battery To Be Charged(User Selectable) 25 to 200 Ah C10 at 48 VDC AH
Maximum Charger Output Current 50 Amp
Number Of Independent Charging Stations 1 Nos.
Charging Cut-off Voltage Per 12V Battery 14.5 Volts
Input Voltage Range Upto 750 VDC VAC
Efficiency Upto 99 %
Ripple (Peak To Peak At Full Load) 0.1 millivolts
Reverse Polarity Protection Yes
Short Circuit Protection Yes
Over Current Protection Yes
AC Surge Protection with MOV
Soft Start And Soft Stop Feature Without Inrush Current Yes
Over Voltage Cutoff Protection Yes
Facility For Charging Deep Discharged Battery Through Pulse Charging. Yes
Cut-in Voltage For Charging A Discharged Battery 10.5 Volts
Cut-off Voltage For Charging A Discharged Battery 14.5 Volts
Not To Charge Battery In Case One Or More Cells Are Internally Short/ Battery Voltage Less Than 10.5V Yes
Digital Display Of Output Voltage And Current Yes
LED Indication For Charging Status, Charged Condition Status And Reverse Polarity Yes
Cabinet Material CRCA Sheet
Cabinet Thickness 2 mm
Length Of Charging Cable For Each Station. 0 metre
Size Of Charging Cable For Each Station. 0 sq. mm
Minimum Operating Temperature 0 Degree Degree Celsius
Maximum Operating Temperature 45 Degree Degree Celsius
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Conformity To The Specification. Yes
Type Test Report No. PN4372
TTC Report Date 18/02/2017
Name Of Lab Systellar Innovations testing Laboratory
Address Of Lab Meerut, Uttar Pradesh, India