× All the transactions performed on 2.0 is available here. To access Market click "Home".

cyber power ols3000e 3000va2700w (cyber power)(cyber power ols3000e)

` 35,865.00

  • MRP: `39850.00

UPS TopologyOnline Double ConversionEnergy Saving TechnologyOnline ECO Mode Efficiency 95Active PFC CompatibilityYesInputGenerator CompatibilityYesNominal Input Voltage Vac230 10Input Voltage Range Vac190 300Adjustable Voltage Range Vac050 Load for 110 300 Vac060 Load for 140 300 Vac080 Load for 160 300 Vac0100 Load for 190 300 VacInput Frequency Hz50 1060 10Input Frequency DetectionAuto-sensingRated Input Current A13.04Input Power Factor0.98Input Connector TypeIEC C20 Detachable Power Cord Plug TypeSchuko OutputCapacity VA3000Capacity Watts2700On Battery WaveformPure Sine WaveOn Battery Voltages Vac208 1220 1230 1240 1Output Voltage SettingConfigurableOn Battery Frequency Hz50 0.560 0.5Output Frequency SettingConfigurableECO Mode Voltage Tolerance 15 Overload ProtectionInternal Current Limiting , Circuit Breaker , FuseOverload Protection Line Mode110120 L.

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM without inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V 1 sinewave,50Hz
  • Minimum VAH - 1872 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 3 KVA
Technology IGBT-PWM without inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V 1 sinewave,50Hz
Backup Time 30 Minutes
Minimum VAH 1872 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer No (only for IGBT-PWM Technology)
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) <3 %
Overall Efficiency 93 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. REGISTRATION ICRS 2015-07941R-41016861
Type Test Certificate Date 18.08.2017
Name Of Lab BIS
Address Of Lab MANAK BHABAN, 9 BAHADUR SHAH ZAFAR MARG,NEW DELHI-110002
Supply & Commissioning YES
Warranty 2 Years

Price Dekho Price Dekho Price List in india