× All the transactions performed on 2.0 is available here. To access Market click "Home".

400a dc or ac autoranging trms clamp-om meter with full multimeter ranges km 062 (kusam-meco)(km 062)

` 8,245.00

  • MRP: `9165.00

3-3/4 Digit 4000 Counts TRMS 400A DC/AC Autoranging Digital Clampmeter with Multimeter Ranges.

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 10
  • Display - Backlit
  • Measurement Type - True RMS
  • AC Current Measurement Range - 0 to 999.9 Ampere
  • AC Voltage Measurement Range - 0 to 1000 Volt
  • Inrush Current (Integration Time) - 100 millisecon
Other Specifications Download Specification
Type Hand Held
Display Backlit
Measurement Type True RMS
AC Current Measurement Range 0 to 999.9 Ampere
AC Current Measurement Accuracy + or - 2 %
AC Voltage Measurement Range 0 to 1000 Volt
AC Voltage Measurement Accuracy Upto 600 Volts + or - 1 %
AC Voltage Measurement Accuracy Beyond 600 Volts + or - 1.5 %
Inrush Current (Integration Time) 100 millisecon
DC Current Measurement Range 0 to 999.9 Ampere
DC Current Measurement Accuracy + or - 2 %
DC Voltage Measurement Range 1000 Volt
DC Voltage Measurement Accuracy + or - 1 %
Resistance Measurement Range 0 to 4000 Ohm
Resistance Measurement Accuracy + or - 1.5 %
Continuity < or = 30 Ohm
Frequency Measurement Range 10 to 400
Frequency Measurement Accuracy + or - 0.5
Jaw Size (Dia In Closed State) 30mm
Satety Rating Category III 600 V of IEC 61010 -2-D31
Operating Temperature Range 0 degree to 40 degree Degree C
Operating Humidity (RH) 80 %
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) CE
Standard Accessories Supplied With The Equipment Test Lead Pair, Battery, User Manual, Carrying Case
Dimensions (H X W X L) 188x63x40 mm x mm x
Weight 218 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 1412344
Test Report Date 14-12-2017
Name Of The Lab Kusam Electrical Industries Ltd.
Warranty 1 Year

Price Dekho Price Dekho Price List in india