× All the transactions performed on 2.0 is available here. To access Market click "Home".

Flame Atomic Absorption Spectrophotometer (Systronics Make)(AA S-263)

` 891,000.00

  • Offered Price: ` 900000.00
  • MRP: `1000000.00

Flame System. There are four-lamps position, and the pre-heat lamp number can be customized, which can minimize the waiting time of operating process. The lamps have the functions of self-optimized and three-dimensional self-adjustment to maximize the energy. The elements have the functions of negative high-voltage self-memory,wavelength scanning, lamps self-optimization and energy optimization with one key step. It is convenient for the testing results to be exported by various formats and operated by office software. Hydride generator can be attached - optional. Standard Accessories - 4 HCL, compressor, Acetylene Gas Cylinder with regulator, Fume Hood. Technical specifications as per literature listed on website...

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC
  • Monochromator - Concave holographic grating with 1200 lines/mm
  • Wavelength Range (user selectable) - 340-960 nm
  • Wavelength Accuracy - +-1 nm
  • Type of Detector - Photodiode
Other Specifications Download Specification
Spectrophotometer Type Microprocessor Based
Display High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC
Monochromator Concave holographic grating with 1200 lines/mm
Wavelength Range (user Selectable) 340-960 nm
Wavelength Resolution 0.2 nm
Wavelength Accuracy +-1 nm
Repeatability +-1 nm
Spectral Bandwidth < 2
Type Of Detector Photodiode
Measuring Modes Transmittance (T), Absorbance (ABS), Concentration (CONC) by K Factor and Multi standards.
Operating Mode Single wavelength: Measuring 1, ABS and CONC
Light Source Tungstan Halogen Lamp
Power 230 V +- 10 50Hz
Standard Accessories To Be Supplied 10 nm path length four (4 nos.) Cuvettes matched with 3 percent
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " NA
Power Requirements 230 V +- 10, 50 Hz
Operating Temperature NA Degree C
Operating Humidity (RH) NA %
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" NA
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) NA
Test Report No. NA
Test Report Date NA
Name Of The Lab NA
Warranty 1 Year

Price Dekho Price Dekho Price List in india