Run denaturing and native polyacrylamide, 2-D, electrophoresis, agarose, and nucleic acid gel electrophoresis Maintain temperature between 1 and 45C with built-in heat exchanger for faster runs with no sacrifice in quality Run two gels simultaneously-or run four gels using accessory divider platesCast single or multiple gels in the two-place casting stand or in the four-gel or ten-gel accessory casters Perform second-dimension separations using two 7 cm IPG strips side-by-side, allowing eight second-dimension separations at once Cast and run wide mini gels using 8 cm glass plates and clamps The key to outstanding, reproducible electrophoresis results is temperature control. Gels unequally cooled on their two faces produce slanted bands appearing as broad or double bands in stained gels. SE 600 Ruby ensures uniform heat in gels because, firstly, https//www.gelifesciences.com/shop/protein-analysis/electrophoresis-and-isoelectric-focusing/protein-electrophoresis-equipment/se-600-vertical.
Other Specifications Download Specification | |
---|---|
Types Of System | Horizontal Gel Electrophoresis system |
Applications | To separate charged molecules like DNA/RNA and proteins according to the size |
Series Of Electrophoresis | Medium |
No. Of Maximum Samples Which Can Run | 112 Nos |
Body Material Of Electrophoresis Unit | Acrylic |
Size Of Unit (WxLxH) | 320290140 mm |
Gel Tray Requirements | The tray should be UV proof and should have integrated fluorescent ruler which should get illuminated on exposure to UV lights for easy and safe calculation of the band movement |
Material Of Gel Tray | Glass |
Width Of The Gel Tray | 18 cm |
Length Of The Gel Tray | 16 cm |
Thickness Of Combs And Colour Code | 1mm-white,1.5mm- Red,2mm-Blue |
All Combs Of Adjustable Height | Yes |
No. Of Wellcombs | 15 Nos |
Width Of Well,cm | 1 cm |
Length Of Well,cm | 2 cm |
Volume Of Gel,ml | 200 ml |
Type Of Electrode | Platinum |
The Base Buffer Volume,ml | 4000 ml |
Details Of Other Components Included | NA |
Required Dye Chemicals | NA |
Specified Voltage For Dye Migration | 0 V |
Dye Migration Rate | 0 cm/hr |
Maxi.output Voltage Of Power Supply Unit | N/A V |
Output Current | N/A mA |
Ouput Wattage,W | 0 W |
Constant Voltage | Yes |
Constant Current | Yes |
Display | LCD display |
Control | Microprocessor controlled |
No. Of Electrode Terminal Ports | 2 Nos |
Alarm For Time Completion | Yes |
Timer Range Up To | 0 minutes |
Autostart After Power Breakdown | Yes |
Operating Voltage | 0 V |
Operating Temperature Range | 0 deg.C |
Power Unit Dimension (LxWxH) | 0 mm |
Weight Of Power Unit | 0 kg |
Warranty Period Of The System | 0 years |
Details Of Consumables To Be Supplied | 0 |
Installation,commissioning And Training Part Of The Supply | Yes |