Convenient design The simple, modular design of miniVE vertical electrophoresis system consolidates all the small parts for electrophoresis and blotting into one convenient unit. Uniform gel temperature is maintained with the tank-style lower buffer chamber. A full tank stabilizes the temperature so that lanes are straight and bands are flat. The blot Module will accept two gel/membrane stacks simultaneously. The lower buffer chamber is designed to hold two Blot Modules, allowing four gels to be blotted at once Load, clamp, and cast The gel module is simultaneously a casting stand and an upper buffer chamber with integrated clamps. Simply assemble the gel sandwich of plates and spacers, clamp it onto the upper buffer chamber, then pivot the sealing gasket and cast the gel. After polymerization, simply release the bottom seal and drop the assembly into the tank for running. No extra parts are needed and no unclamping until the run is finished Extra length and compatible dimensions.
Other Specifications Download Specification | |
---|---|
Types Of System | Horizontal Gel Electrophoresis system |
Applications | To separate charged molecules like DNA/RNA and proteins according to the size |
Series Of Electrophoresis | Small |
No. Of Maximum Samples Which Can Run | 60 Nos |
Body Material Of Electrophoresis Unit | PC |
Size Of Unit (WxLxH) | 192188172 mm |
Gel Tray Requirements | The tray should be UV proof and should have integrated fluorescent ruler which should get illuminated on exposure to UV lights for easy and safe calculation of the band movement |
Material Of Gel Tray | PC |
Width Of The Gel Tray | 10 cm |
Length Of The Gel Tray | 8 cm |
Thickness Of Combs And Colour Code | 1mm-white,1.5mm- Red,2mm-Blue |
All Combs Of Adjustable Height | Yes |
No. Of Wellcombs | 5 Nos |
Width Of Well,cm | 5.08 cm |
Length Of Well,cm | 1 cm |
Volume Of Gel,ml | 44 ml |
Type Of Electrode | Platinum |
The Base Buffer Volume,ml | 1000 ml |
Details Of Other Components Included | ombs, glass plates, spacers, wedge plate separation tool, gel seal, blot module |
Required Dye Chemicals | Standard |
Specified Voltage For Dye Migration | 200 V |
Dye Migration Rate | 16 cm/hr |
Maxi.output Voltage Of Power Supply Unit | 0 V |
Output Current | 0 mA |
Ouput Wattage,W | 0 W |
Constant Voltage | Yes |
Constant Current | Yes |
Display | LCD display |
Control | Microprocessor controlled |
No. Of Electrode Terminal Ports | 0 Nos |
Alarm For Time Completion | Yes |
Timer Range Up To | 0 minutes |
Autostart After Power Breakdown | Yes |
Operating Voltage | 0 V |
Operating Temperature Range | 40 deg.C |
Power Unit Dimension (LxWxH) | 0 mm |
Weight Of Power Unit | 0 kg |
Warranty Period Of The System | 1 years |
Details Of Consumables To Be Supplied | Standard |
Installation,commissioning And Training Part Of The Supply | Yes |