earth resistance tester.
Other Specifications Download Specification | |
---|---|
Display Type | 3 digit LCD display |
Measurable Earth Resistance Range | Auto ranging |
2-pole Method For Resistance Measurement | YES |
3-pole Method For Resistance Measurement | YES |
4-pole Method For Resistance Measurement | NO |
Number Of The Stakes | 2 NOS. |
Material Of The Stakes | Steel |
Length Of The Stakes | 46.5 cm |
Diameter Of The Stakes | 50 cm |
Number Of The Test Leads | 3 Nos. |
Length Of The Test Leads | AL-36:red-15m, yellow-10m, green-5m cm |
No. Of Test Leads With Clamps | n/a Nos. |
Length Of Test Leads With Clamps | n/a cm |
Measuring Range1 For Earth Resistance | 0-40W Ohms |
Measuring Range2 For Earth Resistance | 0-400W Ohms |
Measuring Range3 For Earth Resistance | 0-4000 Ohms |
Measuring Range4 For Earth Resistance | n/a Ohms |
Measuring Range5 For Earth Resistance | n/a Ohms |
Measuring Range6 For Earth Resistance | n/a Ohms |
Measuring Range7 For Earth Resistance | n/a Ohms |
Measurable Earth Resistance Resolution For Range1 | +/- 2 Ohms |
Measurable Earth Resistance Resolution For Range2 | +/- 2 Ohms |
Measurable Earth Resistance Resolution For Range3 | n/a Ohms |
Measurable Earth Resistance Resolution For Range4 | n/a Ohms |
Measurable Earth Resistance Resolution For Range5 | n/a Ohms |
Measurable Earth Resistance Resolution For Range6 | n/a Ohms |
Measurable Earth Resistance Resolution For Range7 | n/a Ohms |
Measurable Earth Resistance Accuracy For Range1 | (2rdg + 3dgts) ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range2 | (2rdg + 3dgts) ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range3 | n/a ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range4 | n/a ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range5 | n/a ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range6 | n/a ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range7 | n/a ±% reading ± digits |
Stakeless Test(Clamp On) | no |
Facility To Measure Earth Voltage | Available |
If Yes,Measurable Earth Voltage Range | 0-400V AC (40-500Hz) Volts |
If Yes,Measurable Earth Voltage Accuracy | (2rdg + 3dgts) % |
Minimum Open Circuit Output Voltage | Low 2mA measuring current permits earth resistance to test without tripping earth leakage current circuit breakers in the circuit. Volts |
Low Battery Indication | Available |
Over Range Indication | Available |
If Yes,Measurable Earth Voltage Resolution | (2rdg + 3dgts) Volts |
Internal Memory | n/a |
Type Of Battery Used In The Power Supply | 1.5 V X 6.Type AA batteries. |
Battery Backup Time | 10 Hours |
Battery Charger Provided With The Meter. | NA |
Weight Of The Tester | 480g approx.(battery included) grams |
Dimensions(LXWXH) | 163(L) X 102(W) X 50(D)mm cmXcmXcm |
Provision For External SD Card | No |
Interface | no |
Operating Temperature Range | 0 40C degree celsius |
Operating Humidity Range | 80 RH Max. % |
All Connecting Cables And Accessories To Be Supplied Along With The Tester. | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. | Test leads(AL-36:red-15m, yellow-10m, green-5m), Auxillary earth bars (2 nos.) Heavy-duty case, Instruction manual, Batteries. |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. | Yes |
Type Test Report No. | 5467898 |
TTC Report Date | 22/10/17 |
Name Of Lab | Kusam Meco |
Address Of Lab | Mumbai |