ATCO 9 Kg Fire Extinguisher, Gross Weight 14.35 Kg, Empty Weight 5.35 Kg, Can Height 595MM, Diameter 175MM, Discharge time minimum 26 Secs, Discharge mechanism - Squeeze Grip Type, Range minimum 2 Meters, Applicable on Class A,B,C and electrically started Fire, A Rating- 4A, B Rating-144B, Can Construction Mig welded, Valve Construction Forging Machining, External Coating of Can Epoxy Polyster Powder coating, Sheet metal thickness 1.60MM, Conforms to BIS Standards, 3 Years WarrantySize Variant - 9KgGross Weight 14.35KgEmpty Weight 5.35KgCan Height 595mmDiameter 175mmDischarge time Approx.26 SecsDischarge Mechanism Squeeze GripRange Not Less Than 2 MetersApplicable on Class A,B,C and electrically started FireA Rating 3A,B Rating 55BCan Construction Mig welded,Valve Construction Forging MachiningInternal Coating of Can NAExternal Coating of Can Epoxy Polyester Powder coatingSheet metal thickness 1.60MMCertifications Conforms to BIS Standards Warranty 3 Year...
Other Specifications Download Specification | |
---|---|
Conformity To Standard | IS:15683:2006 With Latest Amdmnt. |
BIS Marking | Yes |
CM/L No. With Validity Period | 2571457 30/11/2017 |
Type | Stored Pressure |
Trolley | Without Trolley |
Extinguishing Media | Powder Based |
Foam Based Extinguishing Media | NA |
Powder Based Extinguishing Media | ABC |
Clean Agents Based Extinguishing Media | NA |
Expellant Medium | N2 Based |
Fire Extinguisher Capacity( Foam Based/Water Based) | NA Ltrs |
Powder Based Fire Extinguisher Capacity | 9 Kg |
Carbon Dioxide Based Fire Extinguisher Capacity | NA Kg |
Clean Agents Fire Extinguisher Capacity | NA Kg |
Weight Of Filled Portable Fire Extinghuisher | 12.5 Kg |
Test Pressure For Foam Based/Powder(N≥20) / CO2 Based Fire Extinguisher(N≥35) | 35 Bar |
Burst Pressure,Min | 55 Bar |
Discharge Range For Class A Fire Extinguisher(≥2)/Class B (≥1) | 5 Meters |
Effective Discharge Time For Fire Extinguisher, Min | 15 Seconds |
Fire Rating For Class -A Fire Extinguisher | 4A |
Fire Rating For Class -B Fire Extinguisher | 34B |
Fire Extinguisher Suitable For Class -C Fire | YES |
Fire Extinguisher Suitable For Class -D Fire | NO |
Fire Extinguisher Suitable For Class -K Fire | YES |
Rechargebale | YES |
Color Coding | Red |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | YES |
Test Report No. | 21379 |
Test Report Date | 13-0-2014 |
Name Of The Lab | Fire Test & Research Laboratoy |
Address Of The Lab | Delhi |
Operating Temperature | -10 C to + 55 C ° C |
Fire Extinguisher Suitable For Class -E Fire | NO |