Centrifuges for clinical applications are designed to accommodate rotors and centrifuge tubes of varied sizes. The CCF 4000VT is designed to accommodate both a swing out rotor for improved separation as well as a 16 position rotor for high throughput while still remaining compact. The DCF06VT provides a modern but economical centrifuge for basic clinical separations. Rotor position Fixed angle, Tube capacity in ml 5/ 7/ 9/ 15, Max rpm 6500, Lid lock safety Yes, Display Digital, Imbalance detection Yes, Dimension WxDxH in mm 260x244x205, Product code 100DCF00600VT0..
Other Specifications Download Specification | |
---|---|
Centrifuge Design | Bench Top |
Centrifuge Type | Mini centrifuge |
Speed Mode | Fixed Speed |
Rotor Configuration | Fixed Angle |
Interchangeable Rotors | YES |
Material Of Rotor | Aluminium |
Finish Of Rotor | Powder coated |
Autoclavable Rotor At 121 Degree Celsius | YES |
Type Of Drive Motor | Brushless DC Motor |
Controler Type | Microprocessor Controlled |
Body Material | Plastic |
Finish Of Body | Plain finish |
Base Material | Die cast aluminium |
Lid Type | Opaque |
Lid Material | Polycarbonate |
Lid Lock Detector | YES |
Emergency Lid Lock Release | YES |
Automatic Braking | YES |
Number Of Sample Tubes Testable Simultaneously | 6 |
Volume Of The Tube Testable | 15 ml |
Maximum Speed | 6500 RPM |
Minimum Speed | 500 RPM |
Speed Increment Step, If Variable Speed | 100 RPM |
Speed Control Accuracy Of Set Speed (+/-) | 100 RPM |
Maximum Relative Centrifugal Force(RCF) | 3684 x g |
Calibration | Manual Calibration |
Temperature Control Method | Ventilated |
If Refrigerated, Refrigeration System Free From CFC/HCFC | N/A |
Temperature Setting Range(increment Step) | NA Degree Celcius |
Temperature Control Accuracy Of Set Temperature(+/-) | 0 Degree Celcius |
Acceleration Time (full Speed) | 30 sec |
Deceleration Time( Full Stop) | 30 sec |
Number Of Acceleration/deceleration Profiles In-built | 1 |
Timer Provided | YES |
Timer Setting (Increment Step) | 1 to 30 minutes, infinite mode min min |
Input Method/Interface | Digital Front panel With Glove mode |
Display Option/Output Read Out Option | Digital |
Type Of Data Logging Option | NA |
Rotor Imbalance Detection | YES |
Auto Cutoff | YES |
Pulse Mode | NO |
Programmable | NO |
Number Of Storable Programmes,If Programmable | 1 |
Input Voltage With Phase | 230 V |
Power Consumption | 2000 W |
Input Current | 1 A |
Noise Level (maximum) | 60 db |
Ambient Operating Temperature | 40 Degree Celcius |
IP Rating Or Ingress Protection Rating | 21 |
External Dimension: Height | 205 mm |
External Dimension: Width | 260 mm |
External Dimension: Depth | 244 mm |
Weight Including Default Rotor | 4 kg |
Accessories And Spares Included In Standard Pack | Reduction adapters for - 5, 7 ml & 1.5/2 ml tube |
Additional Safety Features | Auto cutoff for Over speed/imbalance/lid lock |
Free Service Available | NO |
Warranty On Rotor And Machine | 1 Years |
Supply Of Free Spare Parts Under Warranty | YES |
Annual Maintenance Contract(AMC) Available After Warranty | YES |
AMC Contract Period | 1 Years |
Product Code Available On Supplier Website | YES |
If Yes, Product Code | DCF06VT |
Firm Certified To ISO9001:2008 Or Latest | YES |
Product Is CE Certified | YES |
If CE Certified, EN/IEC Directives | CE |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | YES |
Test Report No. | 21454 |
Test Report Date | 21-05-2017 |
Name Of The Lab | Star Labs |
Address Of The Lab | Delhi |
Number Of Free Services, If Provided | 0 |