Mastech MS8217, AC/DC Auto ranging Digital Multimeter with 4000 Counts Specifications- DC Voltage 400mV/4V/40V/400V/1000V- AC Voltage 400mV/4V/40V/400V/1000V- DC Current 400A/4000A/40mA/400mA/4A/10A- AC Current 400A/4000A/40mA/400mA/4A/10A- Resistance 400 x3A9/4k x3A9/40k x3A9/400k x3A9/4M x3A9/40M x3A9- Capacitance 4nF/40nF/400nF/4F/40F/100F- Frequency 50Hz/500Hz/5kHz/50kHz/100kHz- Temperature -55 deg Celsius - 1000 deg Celsius Features- Display 4000 Counts - Auto Manual Ranging- Relative Measure- Diode 2.7V Data Hold- Display Backlight- Auto Power Off- Low Battery Display General- Power Supply 1 x 9V Battery- Product Size 185mm x 87mm x 52mm / 7.28 x 3.4 x 2.04- Product Weight 349g / 0.76lb- Safety Rating ETL, CAT II 1000V / CAT III 600V RoHS.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 4000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.5 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 1.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 1.5 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 1.5 % |
Frequency Measurement | 100 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | .01 to 1000 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -50 to 1000 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Not Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category II 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0 C to +40 C |
Operating Humidity (RH) | -30 C to +60 C |
Power Requirements | 230 V +-10 AC, 50 Hz +- 3 through Adaptor |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | 1 |
Total Voltage Of Battery | 2AA |
Standard Accessories Supplied With The Equipment | 1 x Multimeter 1 x Test Lead 1 x Multifunctional Socket 1 x Temperature Probe |
Dimensions (H X W X L) | (18.5 x 8.7 x 5.2)CM mm x mm x |
Weight | 510g gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | NABL/21548 |
Test Report Date | 25-08-2017 |
Name Of The Lab | NABL |
Warranty | 1 Year |