In addition to the facility for precision measurement, test leads for simplified two wire easuring system also supplied as standard accessories. Dust and drip proof.designed to IEC 60529 IP54.
Other Specifications Download Specification | |
---|---|
Display Type | 4 digit LCD display |
Measurable Earth Resistance Range | Auto ranging |
2-pole Method For Resistance Measurement | YES |
3-pole Method For Resistance Measurement | NO |
4-pole Method For Resistance Measurement | YES |
Number Of The Stakes | 4 NOS. |
Material Of The Stakes | Metal |
Length Of The Stakes | 45 cm |
Diameter Of The Stakes | 1 cm |
Number Of The Test Leads | 4 Nos. |
Length Of The Test Leads | 10,20,30,40 cm |
No. Of Test Leads With Clamps | 4 Nos. |
Length Of Test Leads With Clamps | 10,20,30,40 cm |
Measuring Range1 For Earth Resistance | 0.010ohm - 0.099 ohm Ohms Ohms |
Measuring Range2 For Earth Resistance | 0.10 ohm - 0.99ohm Ohms Ohms |
Measuring Range3 For Earth Resistance | 1.0 ohm- 49.9ohm Ohms Ohms |
Measuring Range4 For Earth Resistance | 50.0ohm - 99.5ohm Ohms Ohms |
Measuring Range5 For Earth Resistance | 100ohm - 199ohm Ohms Ohms |
Measuring Range6 For Earth Resistance | 200ohm- 395ohm Ohms Ohms |
Measuring Range7 For Earth Resistance | 400ohm - 590ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range1 | 0.001ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range2 | 0.01ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range3 | 0.1ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range4 | 0.5ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range5 | 1ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range6 | 5ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range7 | 10ohm Ohms Ohms |
Measurable Earth Resistance Accuracy For Range1 | 1+0.01ohm reading digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range2 | 1+0.01ohm reading digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range3 | 1.5+0.1ohm reading digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range4 | 2+0.5ohm reading digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range5 | 3+1ohm reading digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range6 | 6+5ohm reading digits6+5ohm reading digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range7 | 10+10ohm reading digits ±% reading ± digits |
Stakeless Test(Clamp On) | yes |
Facility To Measure Earth Voltage | Available |
If Yes,Measurable Earth Voltage Range | 230 Volts Volts |
If Yes,Measurable Earth Voltage Accuracy | 0.1 % |
Minimum Open Circuit Output Voltage | 36 Volts |
Low Battery Indication | Available |
Over Range Indication | Available |
If Yes,Measurable Earth Voltage Resolution | 2 Volts |
Internal Memory | 99 |
Type Of Battery Used In The Power Supply | R6 (AA) (1.5V) x 6 |
Battery Backup Time | 12 Hours |
Battery Charger Provided With The Meter. | Yes |
Weight Of The Tester | 550g grams |
Dimensions(LXWXH) | 105(L)x158(W)x70(D)mm cmXcmXcm |
Provision For External SD Card | No |
Interface | N/A |
Operating Temperature Range | 0-55 degree celsius degree celsius |
Operating Humidity Range | 95 % |
All Connecting Cables And Accessories To Be Supplied Along With The Tester. | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. | 095A (Earth resistance test leads) 1set (red-20m, yellow-10m, green-5m) 8032 (Auxiliary earth spikes) 1set 7127A (Simplified measurement probe) 1set R6 (AA) 6 9121 (Shoulder strap) Instruction Manual Carrying case : 9084(Carrying case[Soft]:4105A only) : 9165(Carrying case[Hard]:4105A-H only) |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. | Yes |
Type Test Report No. | 52314 |
TTC Report Date | 02.05.2017 |
Name Of Lab | Human Lab |
Address Of Lab | Delhi |