× All the transactions performed on 2.0 is available here. To access Market click "Home".

digital earth resitance meter (kyoritsu)(4105a)

` 33,000.00

  • MRP: `42000.00

In addition to the facility for precision measurement, test leads for simplified two wire easuring system also supplied as standard accessories. Dust and drip proof.designed to IEC 60529 IP54.

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurable Earth resistance range - Auto ranging
  • 2-pole method for resistance measurement - YES
  • 3-pole method for resistance measurement - NO
  • Number of the stakes - 4 NOS.
  • Diameter of the Stakes - 1 cm
Other Specifications Download Specification
Display Type 4 digit LCD display
Measurable Earth Resistance Range Auto ranging
2-pole Method For Resistance Measurement YES
3-pole Method For Resistance Measurement NO
4-pole Method For Resistance Measurement YES
Number Of The Stakes 4 NOS.
Material Of The Stakes Metal
Length Of The Stakes 45 cm
Diameter Of The Stakes 1 cm
Number Of The Test Leads 4 Nos.
Length Of The Test Leads 10,20,30,40 cm
No. Of Test Leads With Clamps 4 Nos.
Length Of Test Leads With Clamps 10,20,30,40 cm
Measuring Range1 For Earth Resistance 0.010ohm - 0.099 ohm Ohms Ohms
Measuring Range2 For Earth Resistance 0.10 ohm - 0.99ohm Ohms Ohms
Measuring Range3 For Earth Resistance 1.0 ohm- 49.9ohm Ohms Ohms
Measuring Range4 For Earth Resistance 50.0ohm - 99.5ohm Ohms Ohms
Measuring Range5 For Earth Resistance 100ohm - 199ohm Ohms Ohms
Measuring Range6 For Earth Resistance 200ohm- 395ohm Ohms Ohms
Measuring Range7 For Earth Resistance 400ohm - 590ohm Ohms Ohms
Measurable Earth Resistance Resolution For Range1 0.001ohm Ohms Ohms
Measurable Earth Resistance Resolution For Range2 0.01ohm Ohms Ohms
Measurable Earth Resistance Resolution For Range3 0.1ohm Ohms Ohms
Measurable Earth Resistance Resolution For Range4 0.5ohm Ohms Ohms
Measurable Earth Resistance Resolution For Range5 1ohm Ohms Ohms
Measurable Earth Resistance Resolution For Range6 5ohm Ohms Ohms
Measurable Earth Resistance Resolution For Range7 10ohm Ohms Ohms
Measurable Earth Resistance Accuracy For Range1 1+0.01ohm reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range2 1+0.01ohm reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range3 1.5+0.1ohm reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range4 2+0.5ohm reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range5 3+1ohm reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range6 6+5ohm reading digits6+5ohm reading digits ±% reading ± digits
Measurable Earth Resistance Accuracy For Range7 10+10ohm reading digits ±% reading ± digits
Stakeless Test(Clamp On) yes
Facility To Measure Earth Voltage Available
If Yes,Measurable Earth Voltage Range 230 Volts Volts
If Yes,Measurable Earth Voltage Accuracy 0.1 %
Minimum Open Circuit Output Voltage 36 Volts
Low Battery Indication Available
Over Range Indication Available
If Yes,Measurable Earth Voltage Resolution 2 Volts
Internal Memory 99
Type Of Battery Used In The Power Supply R6 (AA) (1.5V) x 6
Battery Backup Time 12 Hours
Battery Charger Provided With The Meter. Yes
Weight Of The Tester 550g grams
Dimensions(LXWXH) 105(L)x158(W)x70(D)mm cmXcmXcm
Provision For External SD Card No
Interface N/A
Operating Temperature Range 0-55 degree celsius degree celsius
Operating Humidity Range 95 %
All Connecting Cables And Accessories To Be Supplied Along With The Tester. Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. 095A (Earth resistance test leads) 1set (red-20m, yellow-10m, green-5m) 8032 (Auxiliary earth spikes) 1set 7127A (Simplified measurement probe) 1set R6 (AA) 6 9121 (Shoulder strap) Instruction Manual Carrying case : 9084(Carrying case[Soft]:4105A only) : 9165(Carrying case[Hard]:4105A-H only)
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. Yes
Type Test Report No. 52314
TTC Report Date 02.05.2017
Name Of Lab Human Lab
Address Of Lab Delhi

Price Dekho Price Dekho Price List in india