× All the transactions performed on 2.0 is available here. To access Market click "Home".

apc src 1kin (apc)(src1kin with 30 mins backup)

` 22,650.00

  • MRP: `29999.00

Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS power overload or fault.Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.Cold-start capableProvides temporary battery power when the utility power is out.Excellent footprintSmall UPS footprint provides maximum usage of valuable electrical room floorspaceFrequency and voltage regulationGives higher application availability by correcting poor frequency and voltage conditions without using the battery.Generator compatibilityAllows you to recharge your battery while on generator power.Green modePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.Intelligent Battery ChargingMicroprocessor controlled, 3-stage regulated charging ensures the fastest recharge times without decreasing battery life.LCD Status DisplayProvides.

  • Availability: 50 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM with inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V 1 sinewave,50Hz
  • Minimum VAH - 312 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 1 KVA
Technology IGBT-PWM with inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V 1 sinewave,50Hz
Backup Time 30 Minutes
Minimum VAH 312 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 1 %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. NTS/PPTL/UPS-310/05
Type Test Certificate Date 09/10/2015
Name Of Lab NISAKI TECHNOLOGY SERVICES
Address Of Lab BANGALORE
Supply & Commissioning YES
Warranty 2 Years

Price Dekho Price Dekho Price List in india