True RMS Electronics Logging Multimeter with Trend Capture, Fluke 287 packs more accuracy and convenience into a handheld multi meter than ever before, putting more problem solving power in your hands. It is the ultimate handheld tool for demanding applications that require high-precision.Store up to 15,000 recorded events Large 50,000 count, 1/4 VGA display with white backlight. Multiple sets of measurement information can simultaneously be displayed at the same time,Peak capture to record transients as fast as 250 micro second,Real Time Clock for automatic time stamping of saved readings, CAT III 1000 V / CAT IV 600 V safety rated, Relative mode to remove test lead resistance from low ohms or capacitance measurements, Min/Max/Average with Time Stamp to record signal fluctuations, 0.025 percent Basic DC accuracy, 100 kHz ac bandwidth, Temperature function, Limited lifetime warranty,....
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 4.5 Digit |
Measurement Type | True RMS |
Count | 50000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | .05 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 100 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 300 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | 1 to 100 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -50 to 1000 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 2000 points 500 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category IV 600 V of IEC 61010 |
Overload Protection | Through Fuse |
Operating Temperature Range | -20 °C to +55 °C |
Operating Humidity (RH) | 0 to 90 (0 °C - 37 °C), 0 to 65 (37 °C - 45 °C), 0 to 45 (45 °C - 55 °C) |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CSA |
If Battery Operated, Type And No. Of Battery | 6 AA |
Total Voltage Of Battery | 9 V |
Standard Accessories Supplied With The Equipment | Test Leads,alligator clips, 9V Battery, excluding Temperature probe and Manual |
Dimensions (H X W X L) | 22.2 cm x 10.2 cm x 6 cm mm x mm x mm x mm x |
Weight | 870.9 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 40100189 |
Test Report Date | 28/09/2017 |
Name Of The Lab | Fluke ISO 9001 Certified Lab, USA |
Warranty | 5 Year |