X Ray Processing- Dental OPG Unit Type of EquipmentPantograph Digi-10Power Supply230v /- 10 10 Amp.Column Height230 cmVertical MovementMotor drivenAnode Voltage55 KVP to 85 KVP in step of 1 KVPTube Current10mA fixedX-Ray Tube0.5 mm sq. Fine focusExposure TimeOPG 17 sec. Adult, 14 sec. ChildCEPH 0.2 sec. To 3 sec. TMJ 4 x 4 sec.Film SizeOPG TMJ 6 x 12 10 x 12 CEPH 8 x 10Cassette SizeOPG TMJ Flat 6 x 12 10 x 12 CEPH Flat 8 x 10Safety featuresProvision for Earth Fault, KV Error, Filament Error Thermal ProtectionElectrical Safety ClassificationEN 60601-1 class 1/BDigital Unit.
Other Specifications Download Specification | |
---|---|
Table Top Automatic Medical X Ray Film Processor Machine | Yes |
The Assembly Made Up Of Material Non Corrosive | Yes |
Length Of Machine | 8 ft |
Width Of Machine | 4 ft |
Height Of Machine | 8 ft |
Weight (Empty) | 200 |
Auto Developer , | Yes |
Auto Fixer | Yes |
Auto Washer | Yes |
Auto Dryer | Yes |
Material Of Cabinet | ABS Plastic |
Rollers Mechanism | Motrised |
Rollers Material | PVC with inner pipes of SS-304 Grade |
Minimum Film Size Length X Width | 100 x 100 |
Maximum Film Size Length X Width | 356 x 432 |
Continious Film Roller Transport And Auto Start And Stop Facility | Rigid PVC |
Processing Time: 90 Sec To 200 Sec In Steps Of Six Second With LED Display | Yes |
Processing Capacity Of Size 356mm X 432 Mm In 90 Second Mode | Yes |
Minimum Capacity Of Fixer,Washer And Developer Tank | 5 |
Mimimum Capacity Of Replenishment Developer And Fixer Tank With Overflow Drain Facility | 25 |
Automatic Replenishment | Yes |
Developer And Fixer Temprature Adjustable Throught Automatic Temprature Controller | Yes |
Operating Temp Range | (28-37 )degree degree |
Dryer Temprature(maximum) | 70 degree |
Power Supply | 230 volt A.C |
Maximum Power Consumption | 1.4 kwh |
Water Filter Compatible With Equipment Supplied With Equipment | Yes |
Manual ,auto Stop With Power Saver/standby Mode Facility | Yes |
High Voltage Test 1.5 KV For I Minute | Yes |
Minimum Insulation At 500 V DC | AERB |
Instruction Manual Supplied With Equipment | 1 |
Chemicals/Materail For Running Equipment For Minimum One Month | Manual |
Radiology Certificate For Processed Film | AERB |
Availibility Of Type Test Report For Performance Test | AERB Approval |
Test Report To Shown To Buyer As And When Required | Yes |
Test Report Number & Date | AERB Approval |
Name & Address Of Laboratory | Atomic Energy Regulatory Board |
Certifiacation | TYPE APPROVAL FOR EQUIPMENT |