Analog Oscilloscope - SM203G 30 MHz, 2 Channel (Scientific)(SM203G)

` 22,400.00

  • MRP: `26500.00

Analog Oscilloscope - SM203G 30 MHz, 2 Channel.

  • Availability: 0 In Stock
  • Min. Qty. Per Consignee: 0
  • Operating System - Non -Windows
  • Bandwidth Upgradability - No
  • No. of Analog Channels - 2 Number
  • No. of Digital Channels - NA Number
  • Min. Detectable Pulse Width - NA ns
Other Specifications Download Specification
Type Analog
Operating System Non -Windows
Bandwidth Upgradability No
No. Of Analog Channels 2 Number
Digital Channels No
No. Of Digital Channels NA Number
Record Length Per Digital Channel Simultaneously NA GS/sec
Sampling Rate Per Digital Channel Simultaneously NA Mega Points
Min. Detectable Pulse Width NA ns
Memory Upgradability No
Segmented Memory Feature Availability No
Vertical Sensitivity 1mV/Div to 5 V/Div
Vertical Resolution NA bits
Coupling AC-DC-Ground
Time Base Range 1ns/Div To 0.5s/Div
Trigger Types AC,DC,Line, TV Trigger
Measurements Math Function-Add, Subtract
Frequency Analysis Feature No
In-built Frequency Counter No
In-built Function Generator No
Acquisition Modes NA
Display Type Monochrome
Display Size 14 CM CM
I/O Interface NA
Standard Accessories To Be Supplied Manual : 1 No., Test Prods : 1 Pair, BNC-BNC : 1 No., BNC - Test Lead : 1 No., Power Cord : 1 No.
Operating Temperature Range 0 To 40 Degree C Degree C
Operating Humidity (RH) 90 %
Power Supply 230V +- 10 , 50Hz
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration yes
Test Report No. SMPL/062/17-18
Test Report Date 05.09.17
Name Of The Lab SMPL
Warranty 3 Year
Real Time Bandwidth 30 MHz
Record Length Per Analog Channel Simultaneously NA Mega Point
Sample Rate Per Analog Channel Simultaneously NA GS/sec
Waveform Update Rate NA Waveforms/
Time Base Accuracy 100 PPM

Price Dekho Price Dekho Price List in india