Artico Provides A Flexible, Low-Cost Entry Point For Archive, With The Ability To Scale To Store Petabytes Of Data As Demand Grows. Powered By StorNext Advanced Data Management Policies, Artico Stores And Retains Data In A Tiered Storage System That Intelligently Places The Data On The Right Technology At The Right Time, Both On-Premise Or In The Cloud, Providing The Lowest TCO Model For Storing, Accessing And Protecting Data..
Other Specifications Download Specification | |
---|---|
Type Of Storage | NAS |
Usable Capacity Of Storage System | 33 TB |
Hardware Form Factor Of Unified/NAS System | 6 RU |
Type Of Drives | NL SAS |
RAID Available | Yes |
If Yes ,RAID Type | 6 |
Type Of Front End Ports | FC |
Number Of Front End Port | 2 |
Speed Of Front End Ports In Gbps | 6 Gbps |
Type Of Back End Ports | FC |
Number Of Back End Port | 4 |
Speed Of Back End Ports In Gbps | 10 Gbps |
Number Of Controllers Available In Storage System | 1 |
Supported Global Cache | Yes |
Total Configurable Cache Per Controller. | 64 MB |
Total No Of Drive Slots In The Storage System | 12 |
No Drive Slots Populated In The Storage System | 12 |
Capacity Of Single Drive Populated With The Storage System | 4000 GB |
No Of Drive Slot Available For Scalability | 1 |
No Of Snap Shot Copies | 3 |
Remote Replication | Yes |
Synchronous Replocation Support | Yes |
Asynchronous Replication Support | Yes |
No Of Volume Supported | 2 |
Three Way DR Capability | Yes |
Protocols Supported By The Storage From Day One Such As NFS,CISF,FC , ISCSI | SMB1 (CIFS), SMB2, SMB3, NFSv3, and NFSv4 |
Hot Spare Available | Yes |
If Yes ,No Of Drives Per Hot Spare | 1 |
No Single Point Of Failure (SPOF) With Support For Non Disruptive Replacement Of Hardware Components | Yes |
The Storage Provides Non-disruptive Firmware/micro Code Upgrade, Device Reallocation And Configuration Changes. Storage Architecture Allow New Microcode/Firmware. | Yes |
Network Switch | Available |
If Available, Tpye Of Network Switch (@10Gbps Min) | 0 |
Hardware Form Factor Of Network Switch | 0 RU |
Number Of Network Switches Provided With Storage System | 0 |
Number Of Active Ports In The Network Switch | 0 |
Operating System Platforms Supported | 0 |
Clustering Supported | No |
Deduplication | Yes |
Compression | No |
Operating Temp Range | 10-35 Degree C |
Storage Temp Range | -20-60 Degree C |
Operating Humidity (Rh) | 20-80 % |
Storage Humidity (Rh) | 5-95 % |
BIS Registration Under CRS Of MeiTY | Yes |
BIS Regirstration No. ( Shall Be Furnished When Demaded By The Buyer) | Applied fr |
Storage System Is Compliant With IPv6 | Yes |
Standby Power Consumption Of System | .500KW Watt |
Max Power Consumption Of System | .925KW Watt |
Scope Of Supply | It includes installation, commissioning & integration togather with all necessary software to make the system fully functional as intended. |
Warranty | 1 Year |
Type Of Clustering | 0 |