× All the transactions performed on 2.0 is available here. To access Market click "Home".

analog oscilloscope - sm410d 30 mhz, 2 channel with frequency counter (scientific)(SM 410D)

` 22,000.00

  • MRP: `27000.00

Analog oscilloscope - SM410D 30 mhz, 2 channel With Frequency Counter.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Operating System - Windows
  • Bandwidth Upgradability - No
  • No. of Analog Channels - 2 Number
  • No. of Digital Channels - NA Number
  • Min. Detectable Pulse Width - NA ns
Other Specifications Download Specification
Type Analog
Operating System Windows
Bandwidth Upgradability No
No. Of Analog Channels 2 Number
Digital Channels No
No. Of Digital Channels NA Number
Record Length Per Digital Channel Simultaneously NA GS/sec
Sampling Rate Per Digital Channel Simultaneously NA Mega Points
Min. Detectable Pulse Width NA ns
Memory Upgradability No
Segmented Memory Feature Availability No
Vertical Sensitivity 10mV/Div to 500mV/Div
Vertical Resolution 8 bits
Coupling AC, DC, Ground
Time Base Range 20ns/div to 0.2s/div
Trigger Types AC, DC, Line, Video
Measurements Math - Add, Subtract
Frequency Analysis Feature No
In-built Frequency Counter Yes
In-built Function Generator No
Acquisition Modes NA
Display Type Monochrome
Display Size 14 CM
I/O Interface NA
Standard Accessories To Be Supplied Manual : 1 no., Test Prods : 1 pair, BNC-BNC : 1 no., BNC - Test Lead : 1 no., Power Cord : 1 no.
Operating Temperature Range 0 to 40 Degree C
Operating Humidity (RH) 90 %
Power Supply 230V +- 10 , 50Hz
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration yes
Test Report No. SMPL/146/17-18
Test Report Date 17.01.18
Name Of The Lab SMPL, Indore
Warranty 1 Year
Real Time Bandwidth 30 MHz
Record Length Per Analog Channel Simultaneously NA Mega Point
Sample Rate Per Analog Channel Simultaneously NA GS/sec
Waveform Update Rate NA Waveforms/
Time Base Accuracy 0.05 PPM

Price Dekho Price Dekho Price List in india