Cleaver Scientific Mini Vertical systems are used primarily for protein but also nucleic acid electrophoresis techniques. By combining both functionality and ease of use, the omniPAGE CVS10 systems set the bench mark for simple, versatile vertical mini gel electrophoresis. Each omniPAGE electrophoresis system can accommodate up to 4 handcast gels and 2 commercial precast gels to provide complete flexibility for individual research needs, while unique sliding clamp technology within the PAGE insert facilitates fast, intuitive leak-free casting.With a trouble-free set up and consistent performance, the omniPAGE Mini Vertical systems are perfect for todays laboratories where the ability to generate reproducible results quickly is essential. omniPAGE Mini, 10 x 10cm Dual, 2 sets of Glass Plates, 1mm thick bonded Spacers, 2 x 12 sample, 1mm thick combs including caster. CLAMP VERSION.
Other Specifications Download Specification | |
---|---|
Types Of System | Horizontal Gel Electrophoresis system |
Applications | To separate charged molecules like DNA/RNA and proteins according to the size |
Series Of Electrophoresis | Small |
No. Of Maximum Samples Which Can Run | 80 Nos |
Body Material Of Electrophoresis Unit | acrylic |
Size Of Unit (WxLxH) | 191315 mm |
Gel Tray Requirements | The tray should be UV proof and should have integrated fluorescent ruler which should get illuminated on exposure to UV lights for easy and safe calculation of the band movement |
Material Of Gel Tray | acrylic |
Width Of The Gel Tray | 8 cm |
Length Of The Gel Tray | 8.5 cm |
Thickness Of Combs And Colour Code | 1mm-white,1.5mm- Red,2mm-Blue |
All Combs Of Adjustable Height | Yes |
No. Of Wellcombs | 1 Nos |
Width Of Well,cm | 1 cm |
Length Of Well,cm | 12 cm |
Volume Of Gel,ml | 0 ml |
Type Of Electrode | platinum |
The Base Buffer Volume,ml | 1200 ml |
Details Of Other Components Included | 0 |
Required Dye Chemicals | 0 |
Specified Voltage For Dye Migration | 0 V |
Dye Migration Rate | 0 cm/hr |
Maxi.output Voltage Of Power Supply Unit | 0 V |
Output Current | 0 mA |
Ouput Wattage,W | 0 W |
Constant Voltage | No |
Constant Current | No |
Display | LCD display |
Control | Microprocessor controlled |
No. Of Electrode Terminal Ports | 0 Nos |
Alarm For Time Completion | Yes |
Timer Range Up To | 0 minutes |
Autostart After Power Breakdown | Yes |
Operating Voltage | 0 V |
Operating Temperature Range | 0 deg.C |
Power Unit Dimension (LxWxH) | 0 mm |
Weight Of Power Unit | 0 kg |
Warranty Period Of The System | 1 years |
Details Of Consumables To Be Supplied | 0 |
Installation,commissioning And Training Part Of The Supply | Yes |