Microtek 1Kva online UPs with smf Battery (Microtek)(Microtek NM361K11 online ups)

` 18,950.00

  • MRP: `26500.00

1KVA / 800WMicrotek 1Kva IB Internal BatteryHigh frequency and double conversion online technologyHigh end IGBT based.High end Micro Controller Based.Wide Input voltage rangeAdvanced PFC TechnologyAdvanced Battery ManagementAutomatic Battery Charging in UPS off modeShort Circuit and overload protectionSNMP card slot optionalOver Temperature Protection.EMI / RFI noise filterLCD/LED Display simultaneouslySpecially designed to suit Indian power and environment conditionsGenerator CompatibleSupplying SInewave VoltageIsolation Transformer OptionalDifferent output Voltage settings.Output Frequency fixed at 50Hz or can be synchronized with Input Frequency.Static Bypass Enable or Disable.Outlets Programmable and non programmable.Protection from DC Fan failure.Inbuilt Over Voltage Cut-Off Device.back up indicative up to 30 Minutes. Iso certified co.

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - MOSFET-PWM with inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V 1 sinewave,50Hz
  • Minimum VAH - 800 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 1 KVA
Technology MOSFET-PWM with inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V 1 sinewave,50Hz
Backup Time 30 Minutes
Minimum VAH 800 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 50 %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. R41016713
Type Test Certificate Date 30 june 2017
Name Of Lab BIS
Address Of Lab BIS
Supply & Commissioning Supply Installation till mcb
Warranty 1 Years

Price Dekho Price Dekho Price List in india