1.WALL MOUNTED ,COMPACT DIGITAL ,AERB TYPE APPROVED UNIT, 2 . INTRA ORAL X RAY UNIT BASED ON DC CURRENT ,TUBE VOLTAGE SELECTION 60,65 70 KVP ,TUBE CURRENT 6mA/ 8mA ,FOCAL SPORT 0.7X0.7 mm , TOTAL FILTRATION 2MMAl ,MINIMUM RANGE OF EXPOSURE TIME RANGE -0.02 to 3.2 SEC 3. MANUFACTURE WITH INTERNAL SAFETY STANDARDS FOR RADIATION LEAKAGE , ELECTRONIC SELECTION OF EXPOSURE TIME ACCORDING TO TOOTH NUMBER . IT SHOULD BE POSSIBLE TO SELECT EXPOSURE TIME MANUALLY 4. MACHINE HAVE AUDIBLE AND VISUAL INDICATION OF X RAY ON . 5. X RAY TUBE HEAD SHOULD HAVE SWING ANGULATION OF AT-LEAST 290 DEGREE IN THE VERTICAL PLAIN AND 360 DEGREE CONTINUOUS ROTATION IN THE HORIZONTAL PLAIN . 6. X RAY TUBE HEAD HAVE ANGLE INDICATION.
Other Specifications Download Specification | |
---|---|
Table Top Automatic Medical X Ray Film Processor Machine | Yes |
The Assembly Made Up Of Material Non Corrosive | Yes |
Length Of Machine | 8 |
Width Of Machine | 4 |
Height Of Machine | 8 |
Weight (Empty) | 70 |
Auto Developer , | Yes |
Auto Fixer | Yes |
Auto Washer | Yes |
Auto Dryer | Yes |
Material Of Cabinet | ABS Plastic |
Rollers Mechanism | Motrised |
Rollers Material | PVC with inner pipes of SS-304 Grade |
Minimum Film Size Length X Width | 100 x 100 |
Maximum Film Size Length X Width | 356 x 432 |
Continious Film Roller Transport And Auto Start And Stop Facility | Rigid PVC |
Processing Time: 90 Sec To 200 Sec In Steps Of Six Second With LED Display | Yes |
Processing Capacity Of Size 356mm X 432 Mm In 90 Second Mode | Yes |
Minimum Capacity Of Fixer,Washer And Developer Tank | 5 |
Mimimum Capacity Of Replenishment Developer And Fixer Tank With Overflow Drain Facility | 25 |
Automatic Replenishment | Yes |
Developer And Fixer Temprature Adjustable Throught Automatic Temprature Controller | Yes |
Operating Temp Range | (28-37 )degree degree |
Dryer Temprature(maximum) | 70 degree |
Power Supply | 230 volt A.C |
Maximum Power Consumption | 1.4 kwh |
Water Filter Compatible With Equipment Supplied With Equipment | Yes |
Manual ,auto Stop With Power Saver/standby Mode Facility | Yes |
High Voltage Test 1.5 KV For I Minute | Yes |
Minimum Insulation At 500 V DC | AERB |
Instruction Manual Supplied With Equipment | 1 |
Chemicals/Materail For Running Equipment For Minimum One Month | MANUAL |
Radiology Certificate For Processed Film | AERB |
Availibility Of Type Test Report For Performance Test | AERB APPROVAL |
Test Report To Shown To Buyer As And When Required | Yes |
Test Report Number & Date | AERB APPROVAL |
Name & Address Of Laboratory | ATOMIC ENERGY REGULATORY BOARD |
Certifiacation | ISI 4487074 |