Highest Sensitivity up to 1mV/div After Expand Full band Trig Auto Sweep Circuit Flex Trig mode Select either CH1 or CH2 Signal / External Signal Alt-Trig View 2 in relative Signal Ext Trig Input Power Supply AC 220 10V Specifications Band width DC 20MHz -3dbY Deflection 5mV / div 10V / div Rise Time 18ns, Mag_70ns 17.5ns Max Input 400V DC AC p-p Sweep Mode Auto, Trig, Lock, Single Sweep Rate 0.1s/div 0.2s/div 1-2-5 20 steps, error 5 Trig Source Y1, Y2, ALT, Line, Ext Min Sync. Level Trig 5Hz 20MHz 10Hz 20MHz, Int. 1 div, Ext. 0.2Vp-p Trig Lock 20Hz 10MHz Internal 2 div Freq. Response AC 10Hz 1MHz 3dB DC 0 1 MHz 3dBZ Max. Input 50V DCACp-p Amplitude 0.5 2 Vp-pMin Input Level TTL Level Wave Form Rectangle Frequency 1KHz 2 Standard Accessory Power Chord, Two 20MHz Oscilloscope Probes, Manual Dimensions 320 x 130 x 400mm..
Other Specifications Download Specification | |
---|---|
Type | Analog |
Operating System | Windows |
Bandwidth Upgradability | Yes |
No. Of Analog Channels | 2 Number |
Digital Channels | Yes |
No. Of Digital Channels | 8 Number |
Record Length Per Digital Channel Simultaneously | na GS/sec |
Sampling Rate Per Digital Channel Simultaneously | na Mega Points |
Min. Detectable Pulse Width | na ns |
Memory Upgradability | Yes |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 500mV per Div to 10 V/div |
Vertical Resolution | NA bits |
Coupling | na |
Time Base Range | na |
Trigger Types | Int. Ext.TV |
Measurements | Y Deflection : 5mV / div 10V / div |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | Yes |
Acquisition Modes | as per OEM |
Display Type | Monochrome |
Display Size | 15.30 CM |
I/O Interface | na |
Standard Accessories To Be Supplied | As specified by the OEM |
Operating Temperature Range | 0.5-2 Degree C |
Operating Humidity (RH) | 65 % |
Power Supply | 230V +- 10 , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | 1546 |
Test Report Date | 26/10/2017 |
Name Of The Lab | QMS CERTIFICATION |
Warranty | 1 Year |
Real Time Bandwidth | 20 MHz |
Record Length Per Analog Channel Simultaneously | na Mega Point |
Sample Rate Per Analog Channel Simultaneously | na GS/sec |
Waveform Update Rate | na Waveforms/ |
Time Base Accuracy | 0.05 PPM |