wavelength range of 190-1100 nm, spectral bandwidth of 1 nm, working mode of T,A,C,E and double beam based optical system. Further, the system can deliver fast, medium and slow scanning speeds and have other support options including glass cells, quartz cells, fuse, instrument cover, software CD,USBcable and operation manual. Some of the other standard range of the system includes photometric range of -0.3 - 3.5 A, 0 to 220 T, wavelength accuracy of 0.3 nm, wavelength reproducibility of 0.10 nm as well as photometric accuracy of 0.3 T 0-100 T 0.002 A 0-0.1 A among others. Spectral Bandwidth1nmWorking ModeT,A,C,EOptical SystemDouble beamScanning SpeedFast / Medium / SlowPhotometric Range-0.3 - 3.5 A, 0 to 220 TWavelength Accuracy0.3 nmWavelength Reproducibility 0.10 nmPhotometric Accuracy 0.3 T 0-100 T0.002 A 0-0.1 APhotometric Reproducibility 0.15 TStray Light 0.1 T Nal. 220nm, NaNO2 340 nmBaseline Flatness 0.002 A , SpecificationsWavelengthRange 340 - 960 nm Resolution 0.1, Abs.
Other Specifications Download Specification | |
---|---|
Spectrophotometer Type | Microprocessor Based |
Display | High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC |
Monochromator | Concave holographic grating with 1200 lines/mm |
Wavelength Range (user Selectable) | 340-960 nm |
Wavelength Resolution | 0.2 nm |
Wavelength Accuracy | +-1 nm |
Repeatability | +-1 nm |
Spectral Bandwidth | < 2 |
Type Of Detector | Photodiode |
Measuring Modes | Transmittance (T), Absorbance (ABS), Concentration (CONC) by K Factor and Multi standards. |
Operating Mode | Single wavelength: Measuring 1, ABS and CONC |
Light Source | Tungstan Halogen Lamp |
Power | 230 V +- 10 50Hz |
Standard Accessories To Be Supplied | 10 nm path length four (4 nos.) Cuvettes matched with 3 percent |
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " | AS PER OEM |
Power Requirements | 230 V +- 10, 50 Hz |
Operating Temperature | NA Degree C |
Operating Humidity (RH) | 85 % |
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" | AS PER OEM |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) | AS PER OEM |
Test Report No. | AS PER OEM |
Test Report Date | AS PER OEM |
Name Of The Lab | AS PER OEM |
Warranty | 1 Year |