cathode ray oscilloscope (av tech)(av30)

` 68,500.00

  • MRP: `890000.00

30MHzInbuilt 6 Digit seven segment display frequency counter Dual channel,2 Trace, 6 inch display cathode ray tube, sensitivity triggering up to 1mV/division TV synchronous separation circuit to observe stable TV signal Polarity reversal, CH 1Sync output..

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Operating System - Non -Windows
  • Bandwidth Upgradability - No
  • No. of Analog Channels - 2 Number
  • No. of Digital Channels - NA Number
  • Min. Detectable Pulse Width - NA ns
Other Specifications Download Specification
Type Analog
Operating System Non -Windows
Bandwidth Upgradability No
No. Of Analog Channels 2 Number
Digital Channels No
No. Of Digital Channels NA Number
Record Length Per Digital Channel Simultaneously NA GS/sec
Sampling Rate Per Digital Channel Simultaneously NA Mega Points
Min. Detectable Pulse Width NA ns
Memory Upgradability No
Segmented Memory Feature Availability No
Vertical Sensitivity 2mV/Div to 5 V/Div
Vertical Resolution NA bits
Coupling AC, DC AND GROUND
Time Base Range 0.5 usec/cm to 0.2 s/cm
Trigger Types Automatic and Normal
Measurements NA
Frequency Analysis Feature No
In-built Frequency Counter Yes
In-built Function Generator Yes
Acquisition Modes NA
Display Type Monochrome
Display Size 14 CM
I/O Interface USB
Standard Accessories To Be Supplied 2 No of Passive probe,Power chord,Manual
Operating Temperature Range 5-45 Degree C
Operating Humidity (RH) 95 AT 30 %
Power Supply 230V +- 10 , 50Hz
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration yes
Test Report No. AV/QMS/023
Test Report Date 22/10/2017
Name Of The Lab FACTORY CALIBRATION
Warranty 1 Year
Real Time Bandwidth 30 MHz
Record Length Per Analog Channel Simultaneously NA Mega Point
Sample Rate Per Analog Channel Simultaneously NA GS/sec
Waveform Update Rate NA Waveforms/
Time Base Accuracy 0.05 PPM