Iron removal plant with power operated valve for 5000 ltr per hour.
Other Specifications Download Specification | |
---|---|
Iron Removal Unit | Without |
Prefilter Provided With Flushing Valve In The Iron Removal Unit | NO |
Iron Removal Unit Suitable For Water Supply Equipment | Tubewell |
Discharge Capacity Of The Iron Removal Equipment | 5000 LPH |
Material Of Body Of Iron Removal Equipment | FRP |
Diameter Of Vessel Of Iron Removal Equipment | 533 +/- 100 mm |
Height Of Vessel Of Iron Removal Equipment | 1574 +/- 100 mm |
Number Of Iron Removal Vessel | 1 Nos |
Minimum Thickness Of Vessel Of Iron Removal Equipment | NOT APPLICABLE mm |
Material Of Strainer Plate Of Iron Removal Equipment | NOT APPLICABLE |
Diameter Of Strainer Plate Of Iron Removal Equipment | NOT APPLICABLE mm |
Minimum Thickness Of The Strainer Plate Of Iron Removal Equipment | NOT APPLICABLE mm |
Number Of Strainers For Filtration In Strainer Plate Of Iron Removal Equipment | NOT APPLICABLE Nos |
Number Of Strainers For Backwash In Strainer Plate Of Iron Removal Equipment | NOT APPLICABLE Nos |
Material Of Strainer In Strainer Plate Of Iron Removal Equipment | NOT APPLICABLE |
Quantity Of Iron Removal Media In Iron Removal Vessel | 185 +/- 10 Kg |
Quantity Of Filter Media In Iron Removal Media | 50 +/- 10 Kg |
% Free Space In The Vessel (Top And Bottom) In Iron Removal Vessel | 25% +/- 5% |
Back Wash Valve In Iron Removal Vessel | Automatic Operated Valve System connected to Electric Supply and operated by a timer |
The Accumulated Ferric Is Removed From The Media While Back Washing | YES |
Maximum Iron Content Of Inlet Water | 10 ppm |
Maximum Iron Content Of Outlet Water | 0.3 ppm |
Process By Which Iron Is Removed From Water By Iron Removal Media | Iron removal media work on oxidation process |
Life Of Iron Removal Media | 3 Years |
Cost Of Refilling Of Iron Removal Media | 83250.00 Rupees |
Life Of Iron Removal Unit | 8 Years |
Protective Coating Of Iron Removal Vessel | UV |
Inlet Pipe Size Of Iron Removal Unit | 40 mm |
Space Required For Installation Of Iron Removal Unit | 1.5 Square Metres |
Number Of Valves In Iron Removal Unit | 1 Nos |
Materal Of Valve Of Iron Removal Unit | ABS |
Diameter Of The Valve In Iron Removal Unit | 40 mm |
Pressure Gauge In Iron Removal Unit | YES |
Pressure Release Valve In Iron Removal Unit | YES |
Maximum Line Water Pressure At Ambient Temperature In Iron Removal Unit | 6 Kg/square cm |
Weight Of Iron Removal Unit | 250 + /-20 Kg |
Warranty Period Of Iron Removal Unit | 3 Years |
Arsenic Removal Unit | Without |
Discharge Capacity Of The Arsenic Removal Unit | NOT APPLICABLE LPH |
Arsenic Removal Unit Suitable For Water Supply Equipment | Tubewell |
Material Of Arsenic Removal Vessel | NOT APPLICABLE |
Diameter Of Arsenic Removal Vessel | NOT APPLICABLE mm |
Height Of Arsenic Removal Vessel | NOT APPLICABLE mm |
Minimum Thickness Of Arsenic Removal Vessel | NOT APPLICABLE mm |
Number Of Arsenic Removal Vessel | NOT APPLICABLE Nos |
Material Of Strainer Plate Of Arsenic Removal Vessel | NOT APPLICABLE |
Diameter Of Strainer Plate Of Arsenic Removal Vessel | NOT APPLICABLE mm |
Minimum Thickness Of The Strainer Plate Of Arsenic Removal Vessel | NOT APPLICABLE mm |
Number Of Strainers For Filtration In Arsenic Removal Strainer Plate | NOT APPLICABLE Nos |
Material Of Strainer In Arsenic Removal Strainer Plate | NOT APPLICABLE |
Quantity Of Arsenic Removal Media In Arsenic Removal Vessel | NOT APPLICABLE Kg |
Media Used For Removal Of Arsenic From Water | NOT APPLICABLE |
% Free Space In The Vessel (Top And Bottom) In Arsenic Removal Vessel | NOT APPLICABLE |
Maximum Arsenic Content Of Inlet Water | NOT APPLICABLE ppm |
Maximum Arsenic Content Of Outlet Water | NA ppm |
Life Of Arsenic Removal Media | NOT APPLICABLE Years |
Cost Of Refilling Of Arsenic Removal Media | NOT APPLICABLE Rupees |
Life Of Arsenic Removal Unit | NOT APPLICABLE Years |
Protective Coating Of Arsenic Removal Vessel | NOT APPLICABLE |
Inlet Pipe Size Of Arsenic Removal Unit | NOT APPLICABLE mm |
Space Required For Installation Of Arsenic Removal Unit | NOT APPLICABLE Square Metres |
Number Of Valves In Arsenic Removal Unit | NOT APPLICABLE Nos |
Materal Of Valve In Arsenic Removal Unit | NOT APPLICABLE |
Diameter Of The Valve Of Arsenic Removal Unit | NOT APPLICABLE mm |
Pressure Gauge In Arsenic Removal Unit | NO |
Pressure Release Valve In Arsenic Removal Unit | NO |
Maximum Line Water Pressure At Ambient Temperature In Arsenic Removal Unit | NOT APPLICABLE Kg/square cm |
Weight Of Arsenic Removal Unit | NOT APPLICABLE Kg |
Warranty Period Of Arsenic Removal Unit | NOT APPLICABLE Years |
Iron Removal Media Conform To International Standard | National Science Foundation, USA |
Arsenic Removal Media Conform To International Standard | DIN EN 15029 |
Does The Arsenic Media Have Toxicity Leaching Characteristic Procedure Certificate | YES |
Field Testing Kit For Testing Iron & Arsenic Is Provided | YES |