MEGGER BM5200 is a 5KV battery operated insulation tester with digital and analogue arc display, designed for high voltage insulation resistance testing in the maintenance and servicing of cables, rotating plant machinery, transformers, switchgear and industrial installations. Having insulation resistance range from 100 k upto 1T, with pre-configured diagnostic test for PI, additionally Automatic Discharge, IR IR t functions tests are also available. Selectable AC or DC incl. Frequency Voltmeter functions. The meter is safety rated to CAT III 600V and IP rating as IP40, the short circuit current is 1.4mA /- 0.5mA. The Guard terminal accuracy is at 2 error best in class in the market providing accurate measurement of readings. Battery backup upto 5 hours at 100M load - For more info please refer datasheet of OEM. Warranty one year on main instrument and accessories. Price is inclusive of GST@18percent...
Other Specifications Download Specification | |
---|---|
Type | Portable |
Measurement Range | 200 K Ohm to 1 T Ohm |
Test Voltage | 250, 500, 1000, 2500 and 5000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | Live circuit indicator 30 V to 600v ACDC,50 Hz |
Pass Fail Function | No |
Data Logging | NA |
Software | Not Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 2 milliamper |
Operating Temperature Range | -20 C to 50 C Degree C |
Operating Humidity (RH) | 90 RH non-condensing at 40 C % |
Power Requirements | Battery Operated |
Type Of Battery | Li-ion |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | Battery 1.5V alkaline AA (x8), User guide, Quick start guide, Carrying case with lead storage, 3 m lead set, medium size insulated clips |
Dimensions (H X W X L) | 181 x 285 x 315 mm x mm x |
Weight | 1.45 kg gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 2385 |
Test Report Date | 12 April 2010 |
Name Of The Lab | UKAS-UK |
Warranty | 1 |